0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115

In Stock

Log in for pricing

Write a Review
SKU:
MZ02010115
Condition:
New
Warranty:
5/1 Years
  • 0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115
  • 0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115
  • 0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115
  • 0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115
  • 0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115
  • 0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115
  • 0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115
  • 0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115
  • 0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115
  • 0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115
  • 0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115
  • 0.35-2.25X 2.0 Megapixels CMOS LED Light Track Stand 3D Video Zoom Microscope MZ02010115


Quick Overview
Infinite. Total Magnification: 0.35-2.25X. 1X Objective. Standard Coupler: 0.5X. Zoom Ratio: 1:6.4. Body Mounting Size for Stand: Dia. 39mm. Magnification Detent : 0.5X per pre-set stop. Objective Converter Angle: 35°. Track Stand. LED Light. Light Adjustable. CMOS. 2.0 Megapixels. Windows XP/7/8/10/11. Screen Size: 11.6in. Input Voltage: AC 90-265V 50/60Hz. Input Voltage: DC 12V.

MZ02010115 3D Video Zoom Microscope
Optical System Specifications
Optical SystemInfinite
System Optical Magnification0.35-2.25X
Total Magnification0.35-2.25X
Standard Objective1X Objective
Standard Coupler0.5X
System Field of View Dia. 2.6-17.5mm
System Working Distance96mm
Monocular Video Microscope Objective
1X Objective
Objective Optical SystemInfinite
Objective Optical Magnification1X
Objective TypeSemi-Plan Achromatic Objective
Objective Working Distance97.3mm
Objective Screw ThreadM24x0.75mm
Objective Outer Diameter Dia. 30mm
Barlow LensYes
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Net Weight0.02kg (0.04lbs)
Applied FieldFor MZ0201 Series Microscope
Objective Angle Converter
35° Objective Angle Converter
Objective Converter Angle35°
Magnification of Objective Converter0.75X
Objective Converter Rotatable360°
Objective Converter Operating ModeManual
Objective Converter Working Distance83mm
Objective Converter Vertical/Oblique Working Distance83-136mm
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Net Weight0.05kg (0.11lbs)
Applied FieldFor MZ0201, MV0201 Series Microscope
Zoom Lens Body
0.7-4.5X Video Zoom Body with Detents
Body Optical SystemInfinite
Body Magnification0.7-4.5X
Zoom Range0.7-4.5X
Zoom Ratio1:6.4
Zoom Operating ModeWith the Nosepiece
Body Mounting Size for Stand Dia. 39mm
Magnification Detent 0.5X per pre-set stop
Body Mount Type for CouplerThread Screw
Body Mount Size for Coupler Dia. 24x0.75mm
Nosepiece Adapter Size for Ring Light Dia. 34mm
Objective Screw ThreadM24x0.75mm
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Net Weight0.34kg (0.75lbs)
Track Stand
39mm Track Stand
Stand TypeTrack Stand
Holder Adapter Type Dia. 39mm Scope Holder
Track Length325mm
Base TypeTable Base
Base ShapeRectangle
Stand Throat Depth129mm
Base Dimensions320x305x16mm
Focus ModeManual
Focus Distance200mm
Coarse Focus Distance per Rotation23mm
Focusing Knob Tightness AdjustableTightness Adjustable
Surface TreatmentSpray Paint
MaterialMetal
ColorWhite
Net Weight3.20kg (7.05lbs)
Dimensions320x305x341mm (12.598x12.008x13.425 in. )
Microscope Plate
95x5mm Black White Plate
Plate TypeBlack White Plate
Plate Size Dia. 95x5mm
MaterialPlastic (ABS)
ColorBlack, White
Applied FieldFor ST0201, ST0501, ST1901, ST0801, ST0802 Series Post Stand. ST0203, ST0204 ST0403 Series Track Stand
Ring Light
LED Ring Light (6W ID61mm 64Bulbs)
Light Source TypeLED Light
Ring I.D. Size Dia. 61mm
LED Quantity64
Power Supply AdjustableLight Adjustable
Light Source Illuminance80000Lux
Power Box Panel Meter DisplayPointer Panel Meter/Scale
Power Box Cooling SystemHeat Sink
Power Box Dimensions122x96x43mm
Bulb Color Temperature6500K
Output Power6W
Input VoltageAC 90-265V 50/60Hz
Output VoltageDC 24V
Power Cord Connector TypeUSA 2 Pins
Power Cable Length1.3m
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Net Weight0.42kg (0.93lbs)
Screw ModelM4x24mm
Coupler/C-mount Adapter
0.5X Coupler
Coupler Mount Type for BodyThread Screw
Coupler Mount Size for Body Dia. 24x0.75mm
Adjustable CouplerAdjustable
Coupler for Microscope TypeVideo Zoom Lens Compatible
Coupler Magnification0.5X
For Camera Sensor SizeUnder 1/3 in.
C/CS-Mount CouplerC-Mount
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Applied FieldFor MZ0201 Series Video Zoom Body
LCD Display Digital Camera
11.6 in. LCD Display Digital Camera
Image SensorCMOS
Image Sensor Size1/2.86 in.
Image Sensor Diagonal size6.592mm (0.260 in. )
Camera Maximum Pixels2.0 Megapixels
Camera Resolution1920x1080
Camera Lens MountCS-Mount
Transmission Frame Rate36fps
White BalanceManual/Auto
Gain ControlAdjustable
Exposure ControlManual/Auto
Camera CrosshairsCross Line
Number of Crosshairs4 Movable Crosshairs
Line ColorUser Defined
Capture FunctionYes
Image Capture Output FormatTIFF/JPG/BMP/PNG
Video Output FormatMP4
System RequirementWindows XP/7/8/10/11
Driver InstallationDriver free
Camera Housing MaterialPlastic
Camera Housing Size40x40x58mm
Camera Housing ColorBlack
Max. Supported Memory Card32G
Screen Size11.6in
Screen Aspect Ratio16:9
Monitor Signal FormatNTSC/PAL Auto-Switch
Monitor Max. Resolution1920x1080
Input VoltageDC 12V
Net Weight0.65kg (1.43lbs)
Dimensions280x200x55mm (11.024x7.874x2.165 in. )
Camera Accessories
11.6 in. LCD Display Digital Camera
C/CS Spacer5mm
Mouse OperationYes
Memory TypeSD
Memory Capacity4G
Other Parameters
Surface TreatmentSpray Paint
MaterialMetal
ColorBlack
Net Weight4.75kg (10.47lbs)
Dimensions320x305x341mm (12.598x12.008x13.425 in. )
Series
MZ0201MZ02010115

 


Technical Info

Instructions
Video Zoom LensClose Λ
Video zoom lens, refers to microscope that has only one set of imaging optical paths. It can be considered as a set of dual optical path stereo microscopes. The magnification and multiple range of video zoom lens are usually the same as those of a stereo microscope, but because the objective lens is one, its optical imaging is flat, not stereoscopic.

It has been observed that as most of the parametric features are close to stereo microscopes, video zoom lens is then classified as stereo microscope. In fact, it lacks the most important "stereoscopic" imaging features. Compared with other compound microscopes such as biological metallurgical microscopes, the total optical magnification of video zoom lens is generally below 40X, which is the coverage of low magnification range that these microscopes do not have.

Most of the video continuous zoom lens is to observe the electronic image, not through the eyepiece, but through the camera.
Video zoom lens can have relatively more objective lens and photographic eyepiece multiples for selection. At the same time, video zoom lens can also be designed as parallel light so as to add even more configuration accessories, such as observation eyepieces, aperture diaphragms, coaxial illumination light sources, reticles, and nosepieces that can change the viewing angle and direction, etc.
Regarding accessories of video zoom lens such as the stands and light source etc., generally, all accessories of stereo microscope can be used. Therefore, video zoom lens combination is flexible, compact, with strong adaptability and low cost, suitable for use in industry, especially extensively used in the electronics industry.
InfiniteClose Λ
Microscopes and components have two types of optical path design structures.
One type is finite optical structural design, in which light passing through the objective lens is directed at the intermediate image plane (located in the front focal plane of the eyepiece) and converges at that point. The finite structure is an integrated design, with a compact structure, and it is a kind of economical microscope.
Another type is infinite optical structural design, in which the light between the tube lens after passing the objective lens becomes "parallel light". Within this distance, various kinds of optical components necessary such as beam splitters or optical filters call be added, and at the same time, this kind of design has better imaging results. As the design is modular, it is also called modular microscope. The modular structure facilitates the addition of different imaging and lighting accessories in the middle of the system as required.
The main components of infinite and finite, especially objective lens, are usually not interchangeable for use, and even if they can be imaged, the image quality will also have some defects.

The separative two-objective lens structure of the dual-light path of stereo microscope (SZ/FS microscope) is also known as Greenough.
Parallel optical microscope uses a parallel structure (PZ microscope), which is different from the separative two-object lens structure, and because its objective lens is one and the same, it is therefore also known as the CMO common main objective.
System Optical MagnificationClose Λ
The magnification of the objective lens refers to the lateral magnification, it is the ratio of the image to the real size after the original image is magnified by the instrument. This multiple refers to the length or width of the magnified object.
System optical magnification is the product of the eyepiece and the objective lens (objective lens zoom set) of the optical imaging part within the system.
Optical magnification = eyepiece multiple X objective lens/objective lens set

The maximum optical magnification of the microscope depends on the wavelength of the light to which the object is illuminated. The size of the object that can be observed must be greater than the wavelength of the light. Otherwise, the light cannot be reflected or transmitted, or recognized by the human eye. The shortest wavelength of ultraviolet light is 0.2 microns, so the resolution of the optical microscope in the visible range does not exceed 0.2 microns, or 200 nanometers. This size is converted to the magnification of the microscope, and it is the optical magnification of 2000X. Usually, the compound microscope can achieve 100X objective lens, the eyepiece is 20X, and the magnification can reach 2000X. If it is bigger, it will be called "invalid magnification", that is, the image is large, but the resolution is no longer increased, and no more details and information can be seen.
Total MagnificationClose Λ
Total magnification is the magnification of the observed object finally obtained by the instrument. This magnification is often the product of the optical magnification and the electronic magnification.
When it is only optically magnified, the total magnification will be the optical magnification.

Total magnification = optical magnification X electronic magnification
Total magnification = (objective X photo eyepiece) X (display size / camera sensor target )
System Field of ViewClose Λ
Field of View, is also called FOV.
The field of view, or FOV, refers to the size of the object plane (i.e., the plane of the point of the observed object perpendicular to the optical axis), or of its conjugate plane (i.e., object to primary image distance), represented by a line value.
System field of view is the size of the actual diameter of the image of the terminal display device of the instrument, such as the size of the image in the eyepiece or in the display.

Field of view number refers to the diameter of the field diaphragm of the objective lens, or the diameter of the image plane formed by the field diaphragm.
Field of view number of objective lens = field of view number of eyepiece / (objective magnification / mechanical tube length)

Large field of view makes it easy to observe the full view and more range of the observed object, but the field of view (FOV) is inversely proportional to the magnification and inversely proportional to the resolution, that is, the larger the field of view, the smaller the magnification, and also the lower the resolution of the object to be observed.
There are usually two ways to increase the field of view, one is to replace with an objective lens of a smaller multiple, or to replace with an eyepiece of a smaller multiple.
System Working DistanceClose Λ
Working distance, also referred to as WD, is usually the vertical distance from the foremost surface end of the objective lens of the microscope to the surface of the observed object.
When the working distance or WD is large, the space between the objective lens and the object to be observed is also large, which can facilitate operation and the use of corresponding lighting conditions.
In general, system working distance is the working distance of the objective lens. When some other equipment, such as a light source etc., is used below the objective lens, the working distance (i.e., space) will become smaller.

Working distance or WD is related to the design of the working distance of the objective lens. Generally speaking, the bigger the magnification of the objective lens, the smaller the working distance. Conversely, the smaller the magnification of the objective lens, the greater the working distance.
When it is necessary to change the working distance requirement, it can be realized by changing the magnification of the objective lens.
Objective Optical MagnificationClose Λ
The finite objective is the lateral magnification of the primary image formed by the objective at a prescribed distance.

Infinite objective is the lateral magnification of the real image produced by the combination of the objective and the tube lens.
Infinite objective magnification = tube lens focal length (mm) / objective focal length (mm)

Lateral magnification of the image, that is, the ratio of the size of the image to the size of the object.
The larger the magnification of the objective, the higher the resolution, the smaller the corresponding field of view, and the shorter the working distance.
Objective TypeClose Λ
In the case of polychromatic light imaging, the aberration caused by the light of different wavelengths becomes chromatic aberration. Achromatic aberration is to correct the axial chromatic aberration to the two line spectra (C line, F line); apochromatic aberration is to correct the three line spectra (C line, D line, F line).
The objective is designed according to the achromaticity and the flatness of the field of view. It can be divided into the following categories.

Achromatic objective: achromatic objective has corrected the chromatic aberration, spherical aberration, and comatic aberration. The chromatic portion of the achromatic objective has corrected only red and green, so when using achromatic objective, yellow-green filters are often used to reduce aberrations. The aberration of the achromatic objective in the center of the field of view is basically corrected, and as its structure is simple, the cost is low, it is commonly used in a microscope.

Semi-plan achromatic objective: in addition to meeting the requirements of achromatic objective, the curvature of field and astigmatism of the objective should also be properly corrected.
Plan achromatic objective: in addition to meeting the requirements of achromatic objectives, the curvature of field and astigmatism of the objective should also be well corrected. The plan objective provides a very good correction of the image plane curvature in the field of view of the objective, making the entire field of view smooth and easy to observe, especially in measurement it has achieved a more accurate effect.

Plan semi-apochromatic objective: in addition to meeting the requirements of plan achromatic objective, it is necessary to well correct the secondary spectrum of the objective (the axial chromatic aberration of the C line and the F line).
Plan apochromatic objective: in addition to meeting the requirements of plan achromatic objective, it is necessary to very well correct the tertiary spectrum of the objective (the axial chromatic aberration of the C line, the D line and the F line) and spherochromatic aberration. The apochromatic aberration has corrected the chromatic aberration in the range of red, green and purple (basically the entire visible light), and there is basically no limitation on the imaging effect of the light source. Generally, the apochromatic aberration is used in a high magnification objective.

Objective Working DistanceClose Λ
The objective working distance is the vertical distance from the foremost surface end of the objective of the microscope to the object surface to be observed.
Generally, the greater the magnification, the higher the resolution of the objective, and the smaller the working distance, the smaller the field of view. Conversely, the smaller the magnification, the lower the resolution of the objective, and the greater the working distance, and greater the field of view.
High-magnification objectives (such as 80X and 100X objectives) have a very short working distance. Be very careful when focusing for observation. Generally, it is after the objective is in position, the axial limit protection is locked, then the objective is moved away from the direction of the observed object.
The relatively greater working distance leaves a relatively large space between the objective and the object to be observed. It is suitable for under microscope operation, and it is also easier to use more illumination methods. The defect is that it may reduce the numerical aperture of the objective, thereby reducing the resolution.
Objective Screw ThreadClose Λ
For microscopes of different manufacturers and different models, the thread size of their objectives may also be different.
In general, the objective threads are available in two standard sizes, allowing similar objectives between different manufacturers to be used interchangeably.
One is the British system: RMS type objective thread: 4/5in X 1/36in,
One is metric: M25 X 0.75mm thread.
Objective Angle ConverterClose Λ
Objective angle converter can change the viewing direction of the optical axis of the objective, and it is possible to observe at a suitable angle of the object, such as 90 degrees, 45 degrees, and the like. After adding the angle viewer, the working distance of the original objective will be reduced accordingly.
Observing in the oblique direction is suitable for observing the surface of some objects with "height". For some special positions, it is much easier to see the whole picture. In the electronics industry, the solder joints and solder fillets of electronic components can be seen more clearly.
Zoom RangeClose Λ
Zoom in zoom microscope means to obtain different magnifications by changing the focal length of the objective lens within a certain range through adjustment of some lens or lens set while not changing the position of the object plane (that is, the plane of the point of the observed object perpendicular to the optical axis) and the image plane (that is, the plane of the image imaging focus and perpendicular to the optical axis) of the microscope.
Zoom range refers to the range in which the magnification is from low to high. In the zoom range of the microscope, there is no need to adjust the microscope knob for focusing, and ensure that the image is always clear during the entire zoom process.
The larger the zoom range, the stronger the adaptability of the range for microscope observation, but the image effects at both ends of the low and high magnification should be taken into consideration, the larger the zoom range, the more difficult to design and manufacture, and the higher the cost will be.
Zoom RatioClose Λ
Zoom ratio is the ratio of the maximum magnification / the minimum magnification. Expressed as 1: (ratio of maximum magnification / minimum magnification). If the maximum magnification is 4.5X, the minimum magnification is 0.7X, then the zoom ratio = 4.5 / 0.7 = 6.4, the zoom ratio will be 1:6.4.
Zoom ratio is obtained by the intermediate magnification group of the microscope. When the magnification is increased or decreased by using other objective lenses, the zoom ratio does not change accordingly.
With the NosepieceClose Λ
When the microscope body changes the magnification, it is realized by adjusting the zoom drum or nosepiece. Generally, the lower case of the microscope is used as the zoom drum or nosepiece. When magnification conversion is required, it can be realized by turning the zoom drum or nosepiece.
Magnification Detent Close Λ
In the body of zoom microscope, zooming is continuous. When rotating to a certain position, generally an integral multiple, a positioning structure or detent is added, which has a distinct hand feel during the zooming process, and stops at this position.
When measuring, or testing by factory for unified standard magnification, a magnification detent device can avoid the error caused by the inaccurate multiple positioning of the optical magnification.
Track StandClose Λ
Throughout the focusing range, the track stand moves up and down along the guide rail through the focusing mechanism to achieve the purpose of focusing the microscope. This kind of structure is relatively stable, and the microscope is always kept moving up and down vertically along a central axis. When the focus is adjusted, it is not easy to shake, and there is no free sliding phenomenon. It is a relatively common and safe and reliable accessory.
The size of the stand is generally small, flexible and convenient, and most of them are placed on the table for use, Therefore, together with the post stand, it is also called “desktop or table top stand".
With regard to the height of the stand, most manufacturers usually do not make it very high. If the guide rail is long, it is easy to deform, and relatively more difficult .
Dia. 39mm Scope HolderClose Λ
The 39mm scope holder is a scope holder for connecting to a 39mm microscope body.
Stand Throat DepthClose Λ
Stand throat depth, also known as the throat depth, is an important parameter when selecting a microscope stand. When observing a relatively large object, a relatively large space is required, and a large throat depth can accommodate the object to move to the microscope observation center.
Focusing Knob Tightness AdjustableClose Λ
Different microscope bodies, different human operations, and different requirements for observation and operation, all require adjustment of the pre-tightening force of the stand that support microscope body.
Facing the stand just right, use both hands to reverse the force to adjust the tightness. (face the knob of one side just right, clockwise is to tighten, counterclockwise is to loosen)
In general, after long-time use, the knob will be loose, and adjustment is necessary.
Microscope PlateClose Λ
According to different objects to be observed, the appropriate platen should be selected. The microscope plate materials include black and white, black and white finish; transparent glass, frosted glass, metal, etc.
Standard stands are generally configured with a suitable microscope plate, but different plates may need to be purchased separately.
Black and white microscope plate are made of general plastics, and the different backgrounds in black and white make the object more prominent.
Finish microscope plate eliminates reflections during observation.
Transparent glass plate is used when observing transparent or translucent objects, and the use of transmitted light source is to make the light penetrate the object to be observed as much as possible.
Finish glass plate, with its rough glass surface, can make the transmitted light more uniform and create a diffusing effect, avoiding exposure of the light shadow of the filament directly onto to the observed object.
Metal plate, relatively more solid, is more suitable when it is necessary to operate and cut.
Microscope plate is generally round shaped, on one side of the base there is a spring clip. When installing, align the plate with the clamp and push it in, and then press down the other end, so that the plate is smoothly embedded in to the circular card slot of the bottom plate.
When removing, grab the other end of the clip, push and lift up the plate.
Ring LightClose Λ
Ring light is a kind of "shadowless lamp", which is illuminated from a 360-degree annular angle, and can observe the change of the edge and height of the object to be observed. It is very suitable for surface illumination of non-reflective objects, and is often used to observe and detect the edge of objects, surface structure, traces, etc. such as components on the printed circuit board, liquid crystal glass substrates, metal and non-metal surface dust, scratch damage, various kinds of particles, etc., and is also the most common way of illumination for stereo microscopes.

Circular fluorescent light bulb is a bulb of peripheral illumination with no direction, it requires a reflective bowl to converge the light beam onto the illuminated object below the microscope. The diameter of the tube and the design of the reflective bowl determine the distance and position of the beam convergence point. The LED ring light consists of different LED bulbs. By setting the angle of the bulb, all the illumination beams are concentrated at one focus, and the annular or loop fiber is mostly designed by the incident angle of the fiber exit port.

The central concentration range of the ring lamp usually needs to coincide with the focal length of the objective lens of the stereo microscope. The working distance of the 1X objective lens of stereo microscope is generally about 80-100mm, which is the focus convergence position of most of the ring lamps. Because the external light source itself has a certain height, therefore the concentration center range of the ring light source is generally between 45-65mm. If below 45mm, shadow starts to appear in the middle; if higher than 65mm, the light in the middle will gradually diverge, and the brightness will decrease. When a small objective lens (such as 0.75X/0.5X) is selected, the lighting effect can basically be achieved; but when an objective lens with larger magnification is used and the working distance is relatively small (for example, 2X), the illumination center of the ring lamp will be a "black center", the effect of lighting will be relatively poor.

Ring lights are usually stuck at the bottom of the nosepiece. Tighten the screws. In general, the electrical wires should be pulled to the back of the operating position, the switch or button should be placed on the side for easy operation.
Generally, the ring light needs to be stuck with a lens frame at the bottom of the nosepiece. On the objective frame, there is a card slot for screw fastening. There are also microscope nosepieces that contains a card slot position of its own, and does not need an objective frame.
Light AdjustableClose Λ
The brightness of the light source adjustable is very important in the imaging of the microscope. Since the difference of the numerical aperture of the objective lens of high magnification and low magnification is very big, more incident light is needed to achieve a much better resolution when using a high magnification objective lens. Therefore, when observing through a high magnification objective lens, the brightness required is high; when observing through a low magnification objective lens, the brightness required is low.
When observing different objects, or feature points of the same object at different positions, the brightness needs are also different; including the difference of background light or reflection within the field of view of observation, it has a great influence on the effect of observing the object, and therefore one needs to adjust the brightness of the light source according to each object to be observed.
In the light source capable of providing continuous spectrum, such as a halogen lamp, the brightness adjustment of the light not only adjusts the brightness and intensity of the light, but also changes the spectrum emitted by the light source. When the light source is dark, there are many components of red light, and when the brightness is high, there are more blue spectrum. If the required light is strong and the spectrum needs to be changed, the light can be kept at a brighter intensity, which is solved by adjusting the spectrum by adding a color filter.

Take note of the dimming button on the light source, after the On/Off switch is turned on, normally clockwise is to brighten, and counterclockwise is to darken.
If it is adjusted to the lowest brightness, the light source should normally be lit. If the naked eye still can't see the object being illuminated brightly, you need to adjust the brightness knob to a much bigger position.
Generally, there is scale marking on the dimming knob, which is an imaginary number representing the percentage of brightness, or an electronic digital display, giving the brightness of the light source under the same conditions a marking.
Coupler/C-mount AdapterClose Λ
Coupler/C-mount adapter is an adapter commonly used for connection between the C-adapter camera (industrial camera) and a microscope.
Adjustable CouplerClose Λ
On the coupler/C-mount-adapter, there is an adjustable device to adjust the focal length.
Coupler for Microscope TypeClose Λ
Different coupler/C-mount-adapters are suitable for different microscopes. For some, some adapter accessories need to be replaced. See the applicable range of each coupler/C-mount-adapter for details.
Coupler MagnificationClose Λ
Coupler magnification refers to the line field magnification of the coupler/C-mount-adapter. With different magnifications of the adapter lens, images of different magnifications and fields of view can be obtained. The size of the image field of view is related to the sensor size and the coupler/C-mount-adapter magnification.

Camera image field of view (mm) = sensor diagonal / coupler/C-mount-adapter magnification.

For example: 1/2 inch sensor size, 0.5X coupler/C-mount-adapter coupler, field of view FOV (mm) = 8mm / 0.5 = 16mm.
The field of view number of the microscope 10X eyepiece is usually designed to be 18, 20, 22, 23mm, less than 1 inch (25.4mm). Since most commonly used camera sensor sizes are 1/3 and 1/2 inches, this makes the image field of view on the display always smaller than the field of view of the eyepiece for observation, and the visual perception becomes inconsistent when simultaneously viewed on both the eyepiece and the display. If it is changed to a 0.5X coupler/C-mount-adapter, the microscope image magnification is reduced by 1/2 and the field of view is doubled, then the image captured by the camera will be close to the range observed in the eyepiece.
Some adapters are designed without a lens, and their optical magnification is considered 1X.
For Camera Sensor SizeClose Λ
For the size of the lens field of view of the coupler/C-mount-adapter, in the design process, the size of the camera sensor imaging target should be considered. When the field of view of the lens is smaller than the target plane of the camera, “black border” and “dark corner” will appear.
The general microscope coupler/C-mount adapters are generally designed for the 1/2" camera targets. When a camera of 2/3 or larger target is used, the “dark corner” phenomenon will appear in the field of view. Especially, at present, DSLR cameras generally use large target plane design (1 inch full field of view), when used for microscopic photographing, the general DSLR camera coupler/C-mount adapter will have “black border”.
Generally, the “dark corner” that appears on the field of view is often that the center of the microscope and the camera are not aligned. Adjust the position of the screw on the camera adapter, or turn the camera adapter to adjust or change the effect.
C/CS-Mount CouplerClose Λ
At present, the coupler/C-mount adapter generally adopts the C/CS-Mount adapter to match with the industrial camera. For details, please refer to "Camera Lens Mount".
LCD Display Digital CameraClose Λ
LCD display digital camera is a combination of a digital camera and a display.
CMOSClose Λ
CMOS, or complementary metal oxide semiconductor.
Both CMOS and CCD sensors have their own respective advantages and disadvantages. As a kind of photoelectric conversion sensor, among the current cameras, CMOS is relatively more widely used.
Image Sensor SizeClose Λ
The size of the CCD and CMOS image sensors is the size of the photosensitive device. The larger the area of the photosensitive device, the larger the CCD/CMOS area; the more photons are captured, the better the photographic performance; the higher the signal-to-noise ratio, the larger the photosensitive area, and the better the imaging effect.
The size of the image sensor needs to match the size of the microscope's photographic eyepiece; otherwise, black borders or dark corners will appear within the field of view of observation.
Camera Maximum PixelsClose Λ
The pixel is determined by the number of photosensitive elements on the photoelectric sensor of the camera, and one photosensitive element corresponds to one pixel. Therefore, the more photosensitive elements, the larger the number of pixels; the better the imaging quality of the camera, and the higher the corresponding cost.
The pixel unit is one, for example, 1.3 million pixels means 1.3 million pixels points, expressed as 1.3MP (Megapixels).
Camera ResolutionClose Λ
Resolution of the camera refers to the number of pixels accommodated within unit area of the image sensor of the camera. Image resolution is not represented by area, but by the number of pixels accommodated within the unit length of the rectangular side. The unit of length is generally represented by inch.
Camera Lens MountClose Λ
Industrial camera adapters are usually available in three types:
1. C-Mount: 1" diameter with 32 threads per inch, flange back intercept 17.5mm.
2. CS-Mount: 1" diameter with 32 threads per inch, flange back intercept 12.5mm.
CS-Mount can be converted to a C-Mount through a 5mm spacer, C-mount industrial camera cannot use the CS-mount lens.
3. F-Mount: F-mount is the adapter standard of Nikon lens, also known as Nikon mouth, usually used on large-sized sensor cameras, the flange back intercept is 46.5mm.
Transmission Frame RateClose Λ
Frame rate is the number of output of frames per second, FPS or Hertz  for short. The number of frames per second (fps) or frame rate represents the number of times the graphics process is updated per second.

Due to the physiological structure of the human eye, when the frame rate of the picture is higher than 16fps, it is considered to be coherent, and high frame rate can make the image frame more smooth and realistic. Some industrial inspection camera applications also require a much higher frame rate to meet certain specific needs.
The higher the resolution of the camera, the lower the frame rate. Therefore, this should be taken into consideration during their selection. When needing to take static or still images, you often need a large resolution. When needing to operate under the microscope, or shooting dynamic images, frame rate should be first considered. In order to solve this problem, the general industrial camera design is to display the maximum frame rate and relatively smaller resolution when viewing; when shooting, the maximum resolution should be used; and some cameras need to set in advance different shooting resolutions when taking pictures, so as to achieve the best results.
White BalanceClose Λ
White balance is an indicator that describes the precision of white color generated in the image when the three primary colors of red, green and blue are mixed, which accurately reflects the color condition of the subject. There are manual white balance and automatic white balance.
White balance of the camera is to "restore white objects to white color under any light source." The chromatic aberration phenomenon occurred under different light sources is compensated by enhancing the corresponding complementary color. Automatic white balance can generally be used, but under certain conditions if the hue is not ideal, options of other white balance may be selected.
Camera CrosshairsClose Λ
Camera crosshairs refers to the preset reference line within the camera, which is used to calibrate various positions on the display. The most commonly used is the crosshair, which is to determine the center position of the camera image, and it is very important in measurement. Some cameras also have multiple crosshairs that can be moved to quickly detect and calibrate the size of the object being viewed. Some crosshairs can also change color to adapt to different viewing backgrounds.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.

 


Optical Data

 

Video Microscope Optical Data Sheet
P/NObjective Coupler
MZ02016111  (0.35X)MZ02016131  (0.5X)MZ02016151  (1X)MZ02016419  (1X)MZ02016161  (1.5X)MZ02016171  (2X)
MagnificationMagnificationMagnificationMagnificationMagnificationMagnification
MZ020143110.75X0.18-1.18X0.26-1.69X0.52-3.38X0.52-3.38X0.79-5.06X1.05-6.75X
MZ020144111X0.24-1.58X0.35-2.25X0.7-4.5X0.7-4.5X1.05-6.75X1.4-9X
MZ020145111.5X0.37-2.36X0.52-3.38X1.05-6.75X1.05-6.75X1.57-10.12X2.1-13.5X
MZ020146112X0.49-3.15X0.7-4.5X1.4-9X1.4-9X2.1-13.5X2.8-18X
1. Magnification=Objective Optical Magnification * Body Magnification * Coupler Magnification



Camera Image Sensor Specifications
No.Camera Image Sensor SizeCamera image Sensor Diagonal
(mm)(inch)
11/4 in. 4mm0.157"
21/3 in. 6mm0.236"
31/2.8 in. 6.592mm0.260"
41/2.86 in. 6.592mm0.260"
51/2.7 in. 6.718mm0.264"
61/2.5 in. 7.182mm0.283"
71/2.3 in. 7.7mm0.303"
81/2.33 in. 7.7mm0.303"
91/2 in. 8mm0.315"
101/1.9 in. 8.933mm0.352"
111/1.8 in. 8.933mm0.352"
121/1.7 in. 9.5mm0.374"
132/3 in. 11mm0.433"
141/1.2 in. 12.778mm0.503"
151 in. 16mm0.629"
161/1.1 in. 17.475mm0.688"



Digital Magnification Data Sheet
Image Sensor SizeImage Sensor Diagonal sizeMonitor
Screen Size (11.6in)
Digital Zoom Function
1/2.86 in. 6.592mm44.7
1. Digital Zoom Function= (Screen Size * 25.4) / Image Sensor Diagonal size



Microscope Optical and Digital Magnifications Data Sheet
ObjectiveCouplerCameraMonitorVideo Microscope Optical MagnificationsDigital Zoom FunctionTotal MagnificationField of View (mm)
PNMagnificationPNMagnification Image Sensor SizeImage Sensor Diagonal sizeScreen Size
MZ020143110.75XMZ020161110.35X1/2.86 in. 6.592mm11.6in0.18-1.18X44.78.05-52.75X5.59-36.62mm
MZ020143110.75XMZ020161310.5X1/2.86 in. 6.592mm11.6in0.26-1.69X44.711.62-75.54X3.9-25.35mm
MZ020143110.75XMZ020161611.5X1/2.86 in. 6.592mm11.6in0.79-5.06X44.735.31-226.18X1.3-8.34mm
MZ020143110.75XMZ020164191X1/2.86 in. 6.592mm11.6in0.52-3.38X44.723.24-151.09X1.95-12.68mm
MZ020143110.75XMZ020161511X1/2.86 in. 6.592mm11.6in0.52-3.38X44.723.24-151.09X1.95-12.68mm
MZ020143110.75XMZ020161712X1/2.86 in. 6.592mm11.6in1.05-6.75X44.746.94-301.73X0.98-6.28mm
MZ020144111XMZ020161110.35X1/2.86 in. 6.592mm11.6in0.24-1.58X44.710.73-70.63X4.17-27.47mm
MZ020144111XMZ020161310.5X1/2.86 in. 6.592mm11.6in0.35-2.25X44.715.64-100.58X2.93-18.83mm
MZ020144111XMZ020161611.5X1/2.86 in. 6.592mm11.6in1.05-6.75X44.746.94-301.73X0.98-6.28mm
MZ020144111XMZ020164191X1/2.86 in. 6.592mm11.6in0.7-4.5X44.731.29-201.15X1.46-9.42mm
MZ020144111XMZ020161511X1/2.86 in. 6.592mm11.6in0.7-4.5X44.731.29-201.15X1.46-9.42mm
MZ020144111XMZ020161712X1/2.86 in. 6.592mm11.6in1.4-9X44.762.58-402.3X0.73-4.71mm
MZ020145111.5XMZ020161110.35X1/2.86 in. 6.592mm11.6in0.37-2.36X44.716.54-105.49X2.79-17.82mm
MZ020145111.5XMZ020161310.5X1/2.86 in. 6.592mm11.6in0.52-3.38X44.723.24-151.09X1.95-12.68mm
MZ020145111.5XMZ020161611.5X1/2.86 in. 6.592mm11.6in1.57-10.12X44.770.18-452.36X0.65-4.2mm
MZ020145111.5XMZ020164191X1/2.86 in. 6.592mm11.6in1.05-6.75X44.746.94-301.73X0.98-6.28mm
MZ020145111.5XMZ020161511X1/2.86 in. 6.592mm11.6in1.05-6.75X44.746.94-301.73X0.98-6.28mm
MZ020145111.5XMZ020161712X1/2.86 in. 6.592mm11.6in2.1-13.5X44.793.87-603.45X0.49-3.14mm
MZ020146112XMZ020161110.35X1/2.86 in. 6.592mm11.6in0.49-3.15X44.721.9-140.8X2.09-13.45mm
MZ020146112XMZ020161310.5X1/2.86 in. 6.592mm11.6in0.7-4.5X44.731.29-201.15X1.46-9.42mm
MZ020146112XMZ020161611.5X1/2.86 in. 6.592mm11.6in2.1-13.5X44.793.87-603.45X0.49-3.14mm
MZ020146112XMZ020164191X1/2.86 in. 6.592mm11.6in1.4-9X44.762.58-402.3X0.73-4.71mm
MZ020146112XMZ020161511X1/2.86 in. 6.592mm11.6in1.4-9X44.762.58-402.3X0.73-4.71mm
MZ020146112XMZ020161712X1/2.86 in. 6.592mm11.6in2.8-18X44.7125.16-804.6X0.37-2.35mm
1. Video Microscope Optical Magnifications=Objective Optical Magnification * Body Magnification * Coupler Magnification
2. Digital Zoom Function= (Screen Size * 25.4) / Image Sensor Diagonal size
3. Total Magnification= Video Microscope Optical Magnifications * (Screen Size * 25.4) / Image Sensor Diagonal size
4. Field of View (mm)= Image Sensor Diagonal size / Video Microscope Optical Magnifications

Contains  
Parts Including
PictureP/NProduct Name
ML02241521LED Ring Light (6W ID61mm 64Bulbs)
DC4351111111.6″ LCD Display Digital Camera
MZ020111020.7-4.5X Video Zoom Body with Detents
MZ020144111X Objective
MZ020161310.5X Coupler
ST0203110139mm Track Stand
MZ0201495135° Objective Angle Converter
Desiccant Bag1 Bag
Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Packaging Dimensions(1)38x36x19cm (14.961x14.173x7.480″)
Packaging Dimensions(2)7.5x7.5x14.5cm (2.953x2.953x5.709″)
Packaging Dimensions(3)33x24.5x9cm (12.992x9.646x3.543″)
Packaging Dimensions(4)33x24.5x9cm (12.992x9.646x3.543″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsExpanded Polystyrene
Gross Weight6.30kg (13.89lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)38x36x19cm (14.961x14.173x7.480″)
Transportation Carton Dimensions(2)7.5x7.5x14.5cm (2.953x2.953x5.709″)
Transportation Carton Dimensions(3)33x24.5x9cm (12.992x9.646x3.543″)
Transportation Carton Dimensions(4)33x24.5x9cm (12.992x9.646x3.543″)
Total Gross Weight of Transportation(kilogram)6.30
Total Gross Weight of Transportation(pound)13.89
Quantity of One Transportation Carton1pc

Related Products