3D Rotary Observation Lens Attachment for Microscope Objective, 360 Degree View, 35 Degree Angle Converter

In Stock

Log in for pricing

Write a Review
SKU:
MZ02014951
Condition:
New
  • 3D Rotary Observation Lens Attachment for Microscope Objective, 360 Degree View, 35 Degree Angle Converter
  • 3D Rotary Observation Lens Attachment for Microscope Objective, 360 Degree View, 35 Degree Angle Converter
  • 3D Rotary Observation Lens Attachment for Microscope Objective, 360 Degree View, 35 Degree Angle Converter
  • 3D Rotary Observation Lens Attachment for Microscope Objective, 360 Degree View, 35 Degree Angle Converter


Quick Overview
Objective Converter Angle: 35°. Magnification of Objective Converter: 0.75X. For MZ0201, MV0201 Series Microscope.

MZ02014951 35° Objective Angle Converter
Objective Angle Converter
Objective Converter Angle35°
Magnification of Objective Converter0.75X
Objective Converter Rotatable360°
Objective Converter Operating ModeManual
Objective Converter Working Distance83mm
Objective Converter Vertical/Oblique Working Distance83-136mm
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Net Weight0.05kg (0.11lbs)
Applied FieldFor MZ0201, MV0201 Series Microscope

 


Technical Info

Instructions
Scope Body PartsClose Λ
Nosepiece, also known as revolving nosepiece, can be mounted with several objective, and one of which in turn can be switched to the microscope optical axis for use.
Nosepiece has different configurations, namely, single, triple, quadruple, and quintuple. Each objective has a ball buckle at its position to ensure that the objective is in the exact fixed position of the optical axis. Since any one set of objectives has the same parfocal distance, so when the objective is switched between high and low magnifications for observation, it is almost unnecessary to perform again the focusing operation.
Nosepiece can be divided into two types, namely, inward nosepiece and outward nosepiece, depending on the positional direction. After switching, the tube of inward nosepiece is inclined to the side of the microscope body, which can save people's operating space and prevents it from hitting the lens.

In general, after the objective is mounted onto the nosepiece, no special coaxial processing is required. If necessary, remove the nosepiece, and adjust the position of the end point screw on the dovetail rail behind the nosepiece. If the objective is still off-axis, adjust the optical axis of the condenser to match the optical axis center of the objective.
In the use of microscope, if one set of objective cannot be parfocal, there are many reasons for the problem, but it may be that the nosepiece or the set of objective itself cannot guarantee parfocalness due to problems of processing precision. In this case, after confirming that the high and low magnifications of the objectives at both ends are in focus, adjust the objective of the middle magnification, and usually try to add a thin "shims" to correct.
For normal switching of the objective, it is necessary to push the nosepiece instead of pushing and pulling the objective to prevent the objective and the nosepiece from deviating from the optical axis or loosening, so as to avoid image out of focus or damage.
Objective Angle ConverterClose Λ
Objective angle converter can change the viewing direction of the optical axis of the objective, and it is possible to observe at a suitable angle of the object, such as 90 degrees, 45 degrees, and the like. After adding the angle viewer, the working distance of the original objective will be reduced accordingly.
Observing in the oblique direction is suitable for observing the surface of some objects with "height". For some special positions, it is much easier to see the whole picture. In the electronics industry, the solder joints and solder fillets of electronic components can be seen more clearly.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.
Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsExpanded Polystyrene
Gross Weight0.06kg (0.13lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)15.2x15.2x15.2cm (6x6x6″)
Total Gross Weight of Transportation(kilogram)0.20
Total Gross Weight of Transportation(pound)0.44

Related Products