Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)

In Stock

Log in for pricing

Write a Review
SKU:
ST04030401
Condition:
New
Warranty:
1 Year
Certificate:
ISO9001, ISO13485, ISO14001
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)
  • Microscope Track Stand, 76mm Coarse Focus Rack, Top and Bottom LED Light (Dimmable)


Quick Overview
Track Stand. Dia. 76mm Scope Holder. Track Length: 280mm. Base Dimensions: 240x285x39mm. Focus Distance: 102mm. White Plate. Black Plate. Clear Glass Plate. Plate Size: Dia. 100x2.5mm. Illumination Type: LED Dual Illuminated Light . Top Illumination: Oblique Top Light. Input Voltage: AC 100-240V 50/60Hz. Power Cord Connector Type: USA 3 Pins.

ST04030401 76mm LED Dual Illuminated Light Track Stand
Track Stand
Stand TypeTrack Stand
Holder Adapter Type Dia. 76mm Scope Holder
Track Length280mm
Base TypeIllumination Base
Base ShapeFan-Shape
Stand Throat Depth130mm
Base Dimensions240x285x39mm
Focus ModeManual
Focus Distance102mm
Coarse Focus Distance per Rotation40mm (1.575 in. )
Focusing Knob Tightness AdjustableTightness Adjustable
Illumination TypeLED Dual Illuminated Light
Top IlluminationOblique Top Light
Top Illumination TypeLED
Bottom Illumination TypeLED
Input VoltageAC 100-240V 50/60Hz
Power Cord Connector TypeUSA 3 Pins
Power Cable Length1.8m
Surface TreatmentSpray Paint
MaterialMetal
ColorWhite
Net Weight3.65kg (8.05lbs)
Dimensions240x285x345mm (9.449x11.22x13.583 in. )
Microscope Plate
100x2.5mm Black Plate
Plate TypeBlack Plate
Plate Size Dia. 100x2.5mm
MaterialPlastic (ABS)
ColorBlack
Net Weight0.02kg (0.04lbs)
Applied FieldForST0403, ST0404 Series Track Stand
100x2.5mm White Plate
Plate TypeWhite Plate
Plate Size Dia. 100x2.5mm
MaterialPlastic (ABS)
ColorWhite
Net Weight0.02kg (0.04lbs)
Applied FieldForST0403, ST0404 Series Track Stand
100x2.5mm Clear Glass Plate
Plate TypeClear Glass Plate
Plate Size Dia. 100x2.5mm
MaterialClear Float Glass
Net Weight0.06kg (0.13lbs)
Applied FieldForST0403, ST0404 Series Track Stand

 


Technical Info

Instructions
Microscope StandClose Λ
Microscope stand have many options depending on the needs, especially stereo microscope stand, there are several factors to consider before choosing:
Stability: microscope stand is used to prop up the microscope body. The stand should be selected according to the size of the microscope mainframe. The stability of the stand determines the stability of the microscope in use, and its various adapters and screws must be tightly locked.
Volume size: limited by the working environment and space of the workbench.
Workspace and scope: the size of the workspace of the object being observed and the height of the object being observed should be considered.
Choice of lighting: some stands are equipped with a light source, but some are not, depending on whether there are conditions to add additional lighting.

Operational requirements:
1. Install the stand as required.
2. Arrange a reasonable fixed position for the stand.
3. Carefully tighten the microscope mainframe.
4. Arrange the location of the additional light source reasonably, and place the electric wire in a position that does not interfere with the work.
5. Connect the various kinds of peripheral devices, such as cameras, monitors, computers and so on.
Track StandClose Λ
Throughout the focusing range, the track stand moves up and down along the guide rail through the focusing mechanism to achieve the purpose of focusing the microscope. This kind of structure is relatively stable, and the microscope is always kept moving up and down vertically along a central axis. When the focus is adjusted, it is not easy to shake, and there is no free sliding phenomenon. It is a relatively common and safe and reliable accessory.
The size of the stand is generally small, flexible and convenient, and most of them are placed on the table for use, Therefore, together with the post stand, it is also called “desktop or table top stand".
With regard to the height of the stand, most manufacturers usually do not make it very high. If the guide rail is long, it is easy to deform, and relatively more difficult .
Dia. 76mm Scope HolderClose Λ
The 76mm stand scope holder is the most popular microscope body adapter size, suitable for stereo microscopes produced by most manufacturers.

Place the microscope body in a 76mm scope holder, tighten with screws to avoid shaking when the microscope is in use.
Because this stand scope holder is very common, some special-sized microscopes can also borrow and use this stand, but only need a specific adapter to connect the microscope body with a diameter of less than 76mm.
Illumination BaseClose Λ
Illumination base is a modular light source component, suitable for microscope stand base that has no light source of itself, and it is usually dedicated components supporting some stands.
Illumination base typically includes at least one bottom lighting, and there are also illumination base that includes the circuit portion of the upper light source.
Stand Throat DepthClose Λ
Stand throat depth, also known as the throat depth, is an important parameter when selecting a microscope stand. When observing a relatively large object, a relatively large space is required, and a large throat depth can accommodate the object to move to the microscope observation center.
Focusing Knob Tightness AdjustableClose Λ
Different microscope bodies, different human operations, and different requirements for observation and operation, all require adjustment of the pre-tightening force of the stand that support microscope body.
Facing the stand just right, use both hands to reverse the force to adjust the tightness. (face the knob of one side just right, clockwise is to tighten, counterclockwise is to loosen)
In general, after long-time use, the knob will be loose, and adjustment is necessary.
Microscope PlateClose Λ
According to different objects to be observed, the appropriate platen should be selected. The microscope plate materials include black and white, black and white finish; transparent glass, frosted glass, metal, etc.
Standard stands are generally configured with a suitable microscope plate, but different plates may need to be purchased separately.
Black and white microscope plate are made of general plastics, and the different backgrounds in black and white make the object more prominent.
Finish microscope plate eliminates reflections during observation.
Transparent glass plate is used when observing transparent or translucent objects, and the use of transmitted light source is to make the light penetrate the object to be observed as much as possible.
Finish glass plate, with its rough glass surface, can make the transmitted light more uniform and create a diffusing effect, avoiding exposure of the light shadow of the filament directly onto to the observed object.
Metal plate, relatively more solid, is more suitable when it is necessary to operate and cut.
Microscope plate is generally round shaped, on one side of the base there is a spring clip. When installing, align the plate with the clamp and push it in, and then press down the other end, so that the plate is smoothly embedded in to the circular card slot of the bottom plate.
When removing, grab the other end of the clip, push and lift up the plate.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.
Contains  
Parts Including
PictureP/NProduct Name
SA04141301100x2.5mm Black Plate
SA04141302100x2.5mm White Plate
SA04141304100x2.5mm Clear Glass Plate
Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Packaging Dimensions(1)34x30x58cm (13.386x11.811x22.835″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsExpanded Polystyrene
Gross Weight5.08kg (11.20lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)34x30x58cm (13.386x11.811x22.835″)
Total Gross Weight of Transportation(kilogram)5.08
Total Gross Weight of Transportation(pound)11.20
Quantity of One Transportation Carton1pc

Related Products