Stand Type | Dual Arm Stand |
Vertical Post Height | 384mm |
Maximum Vertical Post Extended Length | 254mm |
Vertical Post Diameter | Dia. 37.2mm |
Cross Adapter Type | Triple (3) Hole Adapter |
Horizontal Arm Type | Double Bar |
Horizontal Arm Length | 570mm |
Horizontal Diameter | Dia. 20mm |
Mounting Hole on the Top of Horizontal Arm | 16mm |
Horizontal Rotation Angle | 360° Degree Rotatable |
Horizontal Arm Travel Distance on Z-Axis | 282mm |
Horizontal Arm Stretch Range | 320mm (12.598 in. ) |
Horizontal Arm Maximum Load | 9.50kg (20.94lbs) |
Horizontal Arm Travel Mode on Horizontal Direction | Ball Bearing |
Horizontal Arm Travel Mode on Z Direction | Manual |
Base Type | Heavy Duty Base |
Base Shape | Rectangle |
Base Dimensions | 285x260x18mm |
Surface Treatment | Electroplating Black |
Material | Metal |
Color | Black |
Net Weight | 18.06kg (39.82lbs) |
Dimensions | 570x285x405mm (22.441x11.220x15.945 in. ) |
Technical Info
Instructions
Microscope StandClose Λ
Microscope stand have many options depending on the needs, especially stereo microscope stand, there are several factors to consider before choosing: Stability: microscope stand is used to prop up the microscope body. The stand should be selected according to the size of the microscope mainframe. The stability of the stand determines the stability of the microscope in use, and its various adapters and screws must be tightly locked. Volume size: limited by the working environment and space of the workbench. Workspace and scope: the size of the workspace of the object being observed and the height of the object being observed should be considered. Choice of lighting: some stands are equipped with a light source, but some are not, depending on whether there are conditions to add additional lighting. Operational requirements: 1. Install the stand as required. 2. Arrange a reasonable fixed position for the stand. 3. Carefully tighten the microscope mainframe. 4. Arrange the location of the additional light source reasonably, and place the electric wire in a position that does not interfere with the work. 5. Connect the various kinds of peripheral devices, such as cameras, monitors, computers and so on. |
Dual Arm StandClose Λ
Dual arm stand is also called double bar stand, or ball bearing boom stand. The method of use of dual arm stand and most of its parameters are mostly the same as that of the boom stand. The difference is that the cross arm has two rods, and is held by one set of bearings, so that the two cross arms can be freely pulled and moved, and they are vertical and cannot be tilted left and right, making it more free and stable than the use of the dual arm stand in the horizontal direction. It is especially suitable for users who need to frequently push and pull, observe and adjust the position in horizontal direction. |
360° Degree RotatableClose Λ
The eyepiece of the microscope can have different viewing or observing directions. When the position of the microscope is uncomfortable, the direction of the eyepiece tube of the microscope can be adjusted, to facilitate observation and operation. Placement method of different viewing angles of the microscope: General direction: the support column is behind the object to be observed Reverse direction: the support column is in front of the object to be observed Lateral direction: the support column is on the side of the object to be observed Rotating eyepiece tube, different microscopes may have different methods, for some, the direction is confirmed when installing the eyepiece tube of the microscope, for some, by rotating the body of the microscope, and for some, by rotating the support member on the support or holder of the microscope. |
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection. For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem. |
Packing | |
Packaging Type | Carton Packaging |
Packaging Material | Corrugated Carton |
Packaging Dimensions(1) | 51x43x18cm (20x17x7″) |
Inner Packing Material | Plastic Bag |
Ancillary Packaging Materials | Expanded Polystyrene |
Gross Weight | 19.58kg (43.17lbs) |
Minimum Packaging Quantity | 1pc |
Transportation Carton | Carton Packaging |
Transportation Carton Material | Corrugated Carton |
Transportation Carton Dimensions(1) | 51x43x18cm (20x17x7″) |
Total Gross Weight of Transportation(kilogram) | 19.58 |
Total Gross Weight of Transportation(pound) | 43.17 |