Microscope Boom Stand, Single Arm, Heavy Duty ST02051101

In Stock

Log in for pricing

Write a Review
SKU:
ST02051101
Condition:
New
Warranty:
1 Year
  • Microscope Boom Stand, Single Arm, Heavy Duty ST02051101
  • Microscope Boom Stand, Single Arm, Heavy Duty ST02051101
  • Microscope Boom Stand, Single Arm, Heavy Duty ST02051101
  • Microscope Boom Stand, Single Arm, Heavy Duty ST02051101
  • Microscope Boom Stand, Single Arm, Heavy Duty ST02051101
  • Microscope Boom Stand, Single Arm, Heavy Duty ST02051101
  • Microscope Boom Stand, Single Arm, Heavy Duty ST02051101
  • Microscope Boom Stand, Single Arm, Heavy Duty ST02051101
  • Microscope Boom Stand, Single Arm, Heavy Duty ST02051101
  • Microscope Boom Stand, Single Arm, Heavy Duty ST02051101
  • Microscope Boom Stand, Single Arm, Heavy Duty ST02051101
  • Microscope Boom Stand, Single Arm, Heavy Duty ST02051101
Instruction Manual
ST0205 Boom Stand Instruction Manual-English.doc

Quick Overview
Boom Stand. Vertical Post Height: 384mm. Vertical Post Diameter: Dia. 37.2mm. Horizontal Arm Length: 544mm. Horizontal Diameter: Dia. 37.2mm. Mounting Hole on the Top of Horizontal Arm: 5/8 in. End Adapter. Base Dimensions: 285x260x18mm.

ST02051101 Boom Stand
Boom Stand
Stand TypeBoom Stand
Vertical Post Height384mm
Maximum Vertical Post Extended Length254mm
Vertical Post Diameter Dia. 37.2mm
Cross Adapter TypeCross Hole Adapter
Horizontal Arm TypeHorizontal Post
Horizontal Arm Length544mm
Horizontal Diameter Dia. 37.2mm
Mounting Hole on the Top of Horizontal Arm5/8 in. End Adapter
Horizontal Rotation Angle360° Degree Rotatable
Horizontal Arm Travel Distance on Z-Axis266mm
Horizontal Arm Stretch Range480mm
Horizontal Arm Maximum Load9.50kg (20.94lbs)
Horizontal Arm Travel Mode on Horizontal DirectionManual
Horizontal Arm Travel Mode on Z DirectionManual
Base TypeHeavy Duty Base
Base ShapeRectangle
Base Dimensions285x260x18mm
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Net Weight18.14kg (39.99lbs)
Dimensions285x260x600mm (11.220x10.236x23.622 in. )

 


Technical Info

Instructions
Microscope StandClose Λ
Microscope stand have many options depending on the needs, especially stereo microscope stand, there are several factors to consider before choosing:
Stability: microscope stand is used to prop up the microscope body. The stand should be selected according to the size of the microscope mainframe. The stability of the stand determines the stability of the microscope in use, and its various adapters and screws must be tightly locked.
Volume size: limited by the working environment and space of the workbench.
Workspace and scope: the size of the workspace of the object being observed and the height of the object being observed should be considered.
Choice of lighting: some stands are equipped with a light source, but some are not, depending on whether there are conditions to add additional lighting.

Operational requirements:
1. Install the stand as required.
2. Arrange a reasonable fixed position for the stand.
3. Carefully tighten the microscope mainframe.
4. Arrange the location of the additional light source reasonably, and place the electric wire in a position that does not interfere with the work.
5. Connect the various kinds of peripheral devices, such as cameras, monitors, computers and so on.
Boom StandClose Λ
Boom stand is also called universal stand.
It is a relatively large pole type stand. The height and length of the stand are big, and it can be freely adjusted in height, length and various angles. Its large weight ensures stable support and occupation of large space, but it can make the microscope free to move in a wide range with convenience. Boom stand is suitable for observing large objects.
The direction of boom stand is flexible, and when in use, various kinds of positions and methods can be adopted, such as front, side, and tilt etc., to facilitate the layout of the workbench. On the side of the crossbar of the boom stand, a 5/8-inch connecting hole is generally left for connecting various focusing mechanisms and microscopes.
The base of the boom stand usually only plays a fixing and supporting role. Under the observation of the microscope, it is an empty workbench, which can be used to place various platforms, work operating surfaces, and tools, etc., and can be freely combined into different working positions. When the base is large, the object to be observed can also be placed.
In industrial places, most of the working positions are fixed. Sometimes, in one working position, a lot of tools, equipment and instruments need to be placed.. Because the microscope is relatively large in size and takes up also a relatively bigger space, and not convenient to move back and forth, therefore for purpose of use, the boom stand can be placed in an appropriate position, and does not need to occupy the most commonly used work tables. When in use, the microscope can be moved over, and pushed to the side when not in use. This is very suitable for use in electronics factories, installation and maintenance, medical and animal anatomy, archaeology and other industries.

Boom stand generally does not have a fixed focusing device, and you can choose a variety of flexible accessories.
Because the stand needs to ensure flexibility, therefore there are many locking buttons in all directions. In any time after adjustment, it must be ensured that each knob is in a locked state to avoid sliding, tilting and flipping of the microscope, thereby damaging the microscope and the items on the workbench.
360° Degree RotatableClose Λ
The eyepiece of the microscope can have different viewing or observing directions. When the position of the microscope is uncomfortable, the direction of the eyepiece tube of the microscope can be adjusted, to facilitate observation and operation.

Placement method of different viewing angles of the microscope:
General direction: the support column is behind the object to be observed
Reverse direction: the support column is in front of the object to be observed
Lateral direction: the support column is on the side of the object to be observed
Rotating eyepiece tube, different microscopes may have different methods, for some, the direction is confirmed when installing the eyepiece tube of the microscope, for some, by rotating the body of the microscope, and for some, by rotating the support member on the support or holder of the microscope.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.
Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Packaging Dimensions(1)51x43x18cm (20x17x7″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsExpanded Polystyrene
Gross Weight20.90kg (46.00lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)51x43x18cm (20x17x7″)
Total Gross Weight of Transportation(kilogram)20.90
Total Gross Weight of Transportation(pound)46.00

Related Products