Curved Arm Stand. Dia. 76mm Scope Holder. Track Length: 520mm. Base Dimensions: 320x305x16mm. Inclination on Vertical Direction: 0-45° . Black White Plate. Plate Size: Dia. 95x5mm. For ST0201, ST0501, ST1901, ST0801, ST0802 Series Post Stand. ST0203, ST0204 ST0403 Series Track Sta.
ST02031332 76mm Angle Viewing Track Stand
Curved Arm Stand
Stand Type | Curved Arm Stand |
Holder Adapter Type | Dia. 76mm Scope Holder |
Track Length | 520mm |
Base Type | Table Base |
Base Shape | Rectangle |
Stand Throat Depth | 120mm |
Base Dimensions | 320x305x16mm |
Inclination on Vertical Direction | 0-45° |
Focus Mode | Manual |
Coarse Focus Distance per Rotation | 23mm |
Focusing Knob Tightness Adjustable | Tightness Adjustable |
Surface Treatment | Spray Paint |
Material | Metal |
Color | Black |
Net Weight | 5.60kg (12.35lbs) |
Microscope Plate
95x5mm Black White Plate | |
Plate Type | Black White Plate |
Plate Size | Dia. 95x5mm |
Material | Plastic (ABS) |
Color | Black, White |
Applied Field | For ST0201, ST0501, ST1901, ST0801, ST0802 Series Post Stand. ST0203, ST0204 ST0403 Series Track Stand |
Technical Info
Instructions
Microscope StandClose Λ
Microscope stand have many options depending on the needs, especially stereo microscope stand, there are several factors to consider before choosing: Stability: microscope stand is used to prop up the microscope body. The stand should be selected according to the size of the microscope mainframe. The stability of the stand determines the stability of the microscope in use, and its various adapters and screws must be tightly locked. Volume size: limited by the working environment and space of the workbench. Workspace and scope: the size of the workspace of the object being observed and the height of the object being observed should be considered. Choice of lighting: some stands are equipped with a light source, but some are not, depending on whether there are conditions to add additional lighting. Operational requirements: 1. Install the stand as required. 2. Arrange a reasonable fixed position for the stand. 3. Carefully tighten the microscope mainframe. 4. Arrange the location of the additional light source reasonably, and place the electric wire in a position that does not interfere with the work. 5. Connect the various kinds of peripheral devices, such as cameras, monitors, computers and so on. |
Dia. 76mm Scope HolderClose Λ
The 76mm stand scope holder is the most popular microscope body adapter size, suitable for stereo microscopes produced by most manufacturers. Place the microscope body in a 76mm scope holder, tighten with screws to avoid shaking when the microscope is in use. Because this stand scope holder is very common, some special-sized microscopes can also borrow and use this stand, but only need a specific adapter to connect the microscope body with a diameter of less than 76mm. |
Stand Throat DepthClose Λ
Stand throat depth, also known as the throat depth, is an important parameter when selecting a microscope stand. When observing a relatively large object, a relatively large space is required, and a large throat depth can accommodate the object to move to the microscope observation center. |
Inclination on Vertical DirectionClose Λ
Conventional microscopic observation is to observe the observed object from top to bottom at a vertical angle of 90 degrees. Inclination on vertical direction observation is to observe from an angle of inclination direction based on the needs of the object to be observed, so as to see more suitable feature points of the observed object. Inclination observation often has ergonomic requirements that allow the observer to adjust the angle at will, and using the microscope in a more comfortable position and sitting posture can help reduce fatigue. In general, all inclination observations are to use microscope with low magnification, which requires a larger field of view and depth of field, otherwise the focusing will be more difficult. |
Focusing Knob Tightness AdjustableClose Λ
Different microscope bodies, different human operations, and different requirements for observation and operation, all require adjustment of the pre-tightening force of the stand that support microscope body. Facing the stand just right, use both hands to reverse the force to adjust the tightness. (face the knob of one side just right, clockwise is to tighten, counterclockwise is to loosen) In general, after long-time use, the knob will be loose, and adjustment is necessary. |
Microscope PlateClose Λ
According to different objects to be observed, the appropriate platen should be selected. The microscope plate materials include black and white, black and white finish; transparent glass, frosted glass, metal, etc. Standard stands are generally configured with a suitable microscope plate, but different plates may need to be purchased separately. Black and white microscope plate are made of general plastics, and the different backgrounds in black and white make the object more prominent. Finish microscope plate eliminates reflections during observation. Transparent glass plate is used when observing transparent or translucent objects, and the use of transmitted light source is to make the light penetrate the object to be observed as much as possible. Finish glass plate, with its rough glass surface, can make the transmitted light more uniform and create a diffusing effect, avoiding exposure of the light shadow of the filament directly onto to the observed object. Metal plate, relatively more solid, is more suitable when it is necessary to operate and cut. Microscope plate is generally round shaped, on one side of the base there is a spring clip. When installing, align the plate with the clamp and push it in, and then press down the other end, so that the plate is smoothly embedded in to the circular card slot of the bottom plate. When removing, grab the other end of the clip, push and lift up the plate. |
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection. For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem. |
Contains | |||||||
Parts Including | |||||||
|
Packing | |
Packaging Type | Carton Packaging |
Packaging Material | Corrugated Carton |
Packaging Dimensions(1) | 64x42x25cm (25.197x16.535x9.842″) |
Inner Packing Material | Plastic Bag |
Ancillary Packaging Materials | Styrofoam |
Gross Weight | 7.35kg (16.20lbs) |
Minimum Packaging Quantity | 1pc |
Transportation Carton | Carton Packaging |
Transportation Carton Material | Corrugated Carton |
Transportation Carton Dimensions(1) | 64x42x25cm (25.197x16.535x9.842″) |
Total Gross Weight of Transportation(kilogram) | 7.35 |
Total Gross Weight of Transportation(pound) | 16.20 |
Quantity of One Transportation Carton | 1pc |