Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics

In Stock

Log in for pricing

Write a Review
SKU:
FS12050125
Condition:
New
Warranty:
5/1 Years
Certificate:
ISO9001
  • Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics
  • Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics
  • Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics
  • Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics
  • Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics
  • Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics
  • Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics
  • Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics
  • Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics
  • Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics
  • Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics
  • Dental 8X Magnification Binocular Fixed Power Stereo Microscope 360° Revolve Lab Equipment for Dentistry Soldering Electronics
  • The ideal cost-effective and high quality stereo microscope for industrial inspection, soldering work, hobbyists and more!
  • The microscope has a total 8X magnification, with 10X eyepieces (one focusable) and 0.8X objective. The working distance is 110mm (4 1/4 inch) with 20mm field of view. Magnification can be changed with optional eyepieces.
  • The 12 inch long, strong metal gooseneck arm and 360° rotating head provides easy height adjustments and rotation.
  • The base of the microscope is weighted for stability and safety.
  • Lighting Options: Different types of lighting options are available.
Professional’s Choice!
Our Best Selling 8X Stereo Microscope is a crowd favorite, designed for a variety of applications, such as industrial inspection, soldering, circuit board work, electronic repairs, dental lab work, hobbyists (coin collecting, stamp collecting) and more.

Clear Optics & High Quality
This microscope features high eyepoint eyepieces with clear optics made from professional quality glass. The interpupillary distance is adjustable. The left eyepiece is also focusable by ±5° to account for all users with eyesight differences. The eyepieces are secured in place with a locking screw to prevent falling out or dust from entering when the head is adjusted.

Long Lasting Durability
With all metal construction, the compact microscope is built with a weighted base, with safety and stability in mind. The flexible metal gooseneck arm makes it easy to see specimens from any angle, without the microscope tipping over.

A built in glass cover protects the objectives from dust and debris, especially in soldering applications. The glass provides clear viewing and does not yellow with age, unlike other plastic materials.

Made with professional grade, high quality materials, this microscope is built to last for years of use.

Upgrades For This Microscope

Additional Magnification Options
The body has a built in (or fixed) 0.8X objective. Standard 10X eyepieces are included. If you would like to change the magnification of this microscope, we carry eyepieces in other magnifications for this microscope. Easily change the magnification by switching the eyepieces. 5X, 15X, 20X eyepieces are also available to achieve a total magnification of 4X, 12X, 16X respectively.

Lighting Options
Consider a LED Ring Light for cool, bright, and even illumination to see bright and clear images.
The objective area has a built in thread, in which a ring adapter (FS12054911) can be purchased separately and installed. This makes it so that virtually any type of standard Ring Light with an inner diameter of at least 52mm can be used with this microscope.

Instruction Manual
FS1204-FS1205-FS1207_Binocular_Fixed_Power_Stereo_Microscope__Instruction_Manual-English.doc


Quick Overview
Finite. Total Magnification: 8X. 10X Eyepiece. 0.8X Built-in Objective. Binocular. Eye Tube Angle: 90°. Eyepiece Field of View: Dia. 20mm. Gooseneck Stand. Depth of Field: 6.5mm.
Suggested Applications
Collecting , Rock & Insect, Electronics , Circuit Board, PCB, Soldering, Mobile Phone, Tablet, Computer Repair, Hobby & Craft , Repair, Industrial , Dental Lab & Production, Jewelry & Gemology , Watch Repair, Veterinary & Zoology , Paleontology

FS12050125 8X Binocular Fixed Power Stereo Microscope
Optical System Specifications
Optical SystemFinite
System Optical Magnification8X
Total Magnification8X
Standard Eyepiece10X Eyepiece
Standard Objective0.8X Built-in Objective
System Field of View Dia. 25mm
System Working Distance110mm
Fixed Power Body
Body Optical SystemFinite
Body Magnification8X
Observation MethodBinocular
Eye Tube Adjustment ModeSiedentopf
Eye Tube Angle90°
Erect/Inverted ImageErect image
Eye Tube RotatableFixed
Interpupillary Adjustment55-75mm
Eye Tube Inner Diameter Dia. 30.5mm
Eye Tube Diopter AdjustableLeft ±5°, Right Not Adjustable
Eye Tube Fixing ModeLocking Screw
Eyepiece TypeStandard Eyepiece
Eyepiece Optical Magnification10X
Plan EyepiecePlan Eyepiece
Eyepiece Size for Eye Tube Dia. 30.5mm
Eyepiece Field of View Dia. 20mm
Eyepoint TypeHigh Eyepoint Eyepiece
Built-in Objective Magnification0.8X
Post Stand
Stand TypeGooseneck Stand
Base TypeTable Base
Base ShapeRound
Focus ModeManual
Other Parameters
Surface TreatmentSpray Paint
MaterialMetal
ColorWhite
Net Weight2.95kg (6.50lbs)
NotesDepth of Field: 6.5mm
Series
FS1205FS12050125

 


Technical Info

Instructions
Stereo MicroscopeClose Λ
Stereo microscopes are also known as the anatomical microscopes, or dissecting microscopes. Many people would refer to stereo microscope as Stereo, and the Continuous Zoom Microscope as Zoom.
Stereo microscopes are a kind of binocular microscope that observes an object with both eyes from different angles, thereby causing a stereoscopic effect.
The stereo microscope adopts two independent optical paths, and the left and right beams in the binocular tube have a certain angle, generally 12°~15°. The objects are observed from different angles of the two optical paths, causing a three-dimensional effect on the eyes, and therefore a stereo microscope is a true 3D microscope.

Compared with other compound microscopes, stereo microscopes belong to the low power optical microscope. The field of view of stereo microscopes has a large diameter, its magnification is generally below 200X for optical magnification. When the magnification is greater than 40X, the stereoscopic effect of the image will be relatively poor.
Therefore, the advantage of the stereo microscope is not that its magnification is large, but that its working distance is long and the depth of field is large, which is particularly suitable for observing objects with a high degree of three-dimensional features.
For compound microscope with a single optical path, what we see is only a flat image. Although most compound microscopes have two eyepieces, what we actually see is one and the same image, and this is just to facilitate the observation habits of our two eyes. The stereo microscope has two optical paths (two objective lenses or one common objective lens), and only the three-dimensional sense produced under observation of the two optical paths can make people judge the three-dimensional spatial position of the observed object, which can generate a sense of distance under the microscope. Therefore, only stereo microscope can be used for operation under the microscope which is very suitable for surgery, dissection, industrial welding, assembly, precision instrument repair and so on.

The stereo microscope can be equipped with a wide range of accessories. It can be combined with various digital cameras and photographic interfaces, microscope cameras, eyepiece cameras and image analysis software to form a digital imaging system. It can be connected to a computer for analysis and processing, and its lighting system also has different options for illumination, such as reflected light, transmitted light, etc.
Stereoscopic microscopes are widely used in various fields, such as biology, medicine, agriculture, forestry, marine life, and other various departments. They are especially used in industry, for macroscopic surface observation, analysis, and microscopic operations.

Stereoscopic microscopes were invented by American instrument engineer Horatio S. Greenough in the 1890s, manufactured by Carl Zeiss Company of Germany, and are widely used in scientific research, archaeological exploration, industrial quality control, biopharmaceuticals, and more.


Stereo Microscope Quick Operation Steps
Step 1
In the working position, place the microscope on the workbench after installation.
Connect the power source, and turn on the light source.
Place an observation sample (also known as specimen) such as a coin etc. under the microscope or on the base.
Adjust the focus knob of the stand by visually measuring the height, or based on the working distance parameters of the objective lens used.

Step 2
Adjust the zoom knob of the microscope to the lowest magnification. Find the approximate image by adjusting the focus knob. Find a certain feature point of the sample in approximately the center position.
Align the feature point of the specimen and gradually adjust to a large magnification.
Adjust the lift set of the microscope to find the focal plane of the highest magnification. During the adjustment process, use a sample with obvious feature points (such as a coin) to compare the sharpness of the image.
Turn the zoom knob again to the lowest magnification. It is possible that the image may be out of focus. At this time, do not adjust the focusing knob. Simply adjust the diopters on the two eyepieces to accommodate differences in eye observations (diopter varies from person to person).
Adjust the viewing distance of the eyepiece to achieve a comfortable position.
At this point, the microscope is already parfocal, i.e., when the microscope is changed from high power to low power, the entire image is in the focal plane. To observe the same sample, it is not necessary to adjust other parts of the microscope. Only the zoom knob is needed to zoom in on the specimen for observation.

Step 3
Adjust the light source, including the brightness and angle of incidence to get the best image or see additional details.

Step 4
Adjust any other necessary equipment such as the photographic eyepieces, cameras, etc., to show the image on the display or to find the sharpest image.

When using binocular observation and the left and right images or sharpness is not the same, first adjust the diopter adjustment on the eyepiece. This adjusts the parallax of the two eyes, so that the image of the two eyes are consistent. It is normal to feel viewing fatigue when using a microscope for a long time. Take a break before working again to adapt your eyes to using the microscope. If the microscope is used for too long, or if there is a problem inside the microscope due to large temperature difference, vibration, etc., please contact your dealer or our service staff on the BoliOptics website.
FiniteClose Λ
Microscopes and components have two types of optical path design structures.
One type is finite optical structural design, in which light passing through the objective lens is directed at the intermediate image plane (located in the front focal plane of the eyepiece) and converges at that point. The finite structure is an integrated design, with a compact structure, and it is a kind of economical microscope.
Another type is infinite optical structural design, in which the light between the tube lens after passing the objective lens becomes "parallel light". Within this distance, various kinds of optical components necessary such as beam splitters or optical filters call be added, and at the same time, this kind of design has better imaging results. As the design is modular, it is also called modular microscope. The modular structure facilitates the addition of different imaging and lighting accessories in the middle of the system as required.
The main components of infinite and finite, especially objective lens, are usually not interchangeable for use, and even if they can be imaged, the image quality will also have some defects.

The separative two-objective lens structure of the dual-light path of stereo microscope (SZ/FS microscope) is also known as Greenough.
Parallel optical microscope uses a parallel structure (PZ microscope), which is different from the separative two-object lens structure, and because its objective lens is one and the same, it is therefore also known as the CMO common main objective.
System Optical MagnificationClose Λ
The magnification of the objective lens refers to the lateral magnification, it is the ratio of the image to the real size after the original image is magnified by the instrument. This multiple refers to the length or width of the magnified object.
System optical magnification is the product of the eyepiece and the objective lens (objective lens zoom set) of the optical imaging part within the system.
Optical magnification = eyepiece multiple X objective lens/objective lens set

The maximum optical magnification of the microscope depends on the wavelength of the light to which the object is illuminated. The size of the object that can be observed must be greater than the wavelength of the light. Otherwise, the light cannot be reflected or transmitted, or recognized by the human eye. The shortest wavelength of ultraviolet light is 0.2 microns, so the resolution of the optical microscope in the visible range does not exceed 0.2 microns, or 200 nanometers. This size is converted to the magnification of the microscope, and it is the optical magnification of 2000X. Usually, the compound microscope can achieve 100X objective lens, the eyepiece is 20X, and the magnification can reach 2000X. If it is bigger, it will be called "invalid magnification", that is, the image is large, but the resolution is no longer increased, and no more details and information can be seen.
Total MagnificationClose Λ
Total magnification is the magnification of the observed object finally obtained by the instrument. This magnification is often the product of the optical magnification and the electronic magnification.
When it is only optically magnified, the total magnification will be the optical magnification.

Total magnification = optical magnification X electronic magnification
Total magnification = (objective X photo eyepiece) X (display size / camera sensor target )
System Field of ViewClose Λ
Field of View, is also called FOV.
The field of view, or FOV, refers to the size of the object plane (i.e., the plane of the point of the observed object perpendicular to the optical axis), or of its conjugate plane (i.e., object to primary image distance), represented by a line value.
System field of view is the size of the actual diameter of the image of the terminal display device of the instrument, such as the size of the image in the eyepiece or in the display.

Field of view number refers to the diameter of the field diaphragm of the objective lens, or the diameter of the image plane formed by the field diaphragm.
Field of view number of objective lens = field of view number of eyepiece / (objective magnification / mechanical tube length)

Large field of view makes it easy to observe the full view and more range of the observed object, but the field of view (FOV) is inversely proportional to the magnification and inversely proportional to the resolution, that is, the larger the field of view, the smaller the magnification, and also the lower the resolution of the object to be observed.
There are usually two ways to increase the field of view, one is to replace with an objective lens of a smaller multiple, or to replace with an eyepiece of a smaller multiple.
System Working DistanceClose Λ
Working distance, also referred to as WD, is usually the vertical distance from the foremost surface end of the objective lens of the microscope to the surface of the observed object.
When the working distance or WD is large, the space between the objective lens and the object to be observed is also large, which can facilitate operation and the use of corresponding lighting conditions.
In general, system working distance is the working distance of the objective lens. When some other equipment, such as a light source etc., is used below the objective lens, the working distance (i.e., space) will become smaller.

Working distance or WD is related to the design of the working distance of the objective lens. Generally speaking, the bigger the magnification of the objective lens, the smaller the working distance. Conversely, the smaller the magnification of the objective lens, the greater the working distance.
When it is necessary to change the working distance requirement, it can be realized by changing the magnification of the objective lens.
Fixed Power BodyClose Λ
Fixed power body generally refers to binocular stereo microscope that has only one fixed magnification. When it is necessary to change the magnification, it can be achieved only by replacing the objective lens or eyepiece.
SiedentopfClose Λ
For siedentopf eyetube, when changing the interpupillary distance, it requires two hands pushing or pulling the two eyetubes left and right simultaneously, and the two eyepiece tubes or eyetubes will change their position at the same time.
Eye Tube AngleClose Λ
Usually the Microscope Eyetube is 45°, some is 30°, Tiltable Eyetube Angle design of a microscope is also known as the ergonomics microscope.
0-30° or 0-45° is an ergonomic design. When the mechanical tube length / focal length of the tube of the microscope is relatively big, the microscope is relatively high, and the user's height or the seat of the work desk is not suitable, long-term use of microscope may cause sitting discomfort.
Eyepiece tube with variable angle can freely adjust the angle without lowering the head. Especially when it is close to 0 degree and the human eye is close to horizontal viewing, long-time or long-term use can avoid fatigue damage to the cervical vertebra.
Erect/Inverted ImageClose Λ
After imaging through a set of objective lenses, the object observed and the image seen by the human eye is inverted. When the observed object is manipulated, move the specimen or object, the image will move in the opposite direction in the field of view. Most of the biological microscopes are reversed-phase designs.
When needing to operate works with accurate direction, it is necessary to design it into a forward microscope. Generally stereo microscopes and metallurgical microscopes are all of erect image design.
When observing through the camera and display, the erect and inverted image can be changed by the orientation of the camera.
Interpupillary AdjustmentClose Λ
The distance between the two pupils of the human eye is different. When the image of exit pupil of the two eyepieces of the microscope are not aligned with the entry pupil of the eye, the two eyes will see different images, which can cause discomfort.
Adjust the distance between the two eyepieces, to accommodate or adapt to the pupil distance of the observer's eyes. The adjustment range is generally between 55-75mm.
Eye Tube Diopter AdjustableClose Λ
For most people, their two eyes, the left and the right, have different vision; for the eyepiece tube, the eyepoint height of the eyepiece can be adjusted to compensate for the difference in vision between the two eyes, so that the imaging in the two eyes is clear and consistent.
The range of adjustment of the eyepiece tube is generally diopter plus or minus 5 degrees, and the maximum differential value between the two eyepieces can reach 10 degrees.

Monocular adjustable and binocular adjustable: some microscopes have one eyepiece tube adjustable, and some have two eyepiece tubes adjustable. First, adjust one eyepiece tube to the 0 degree position, adjust the microscope focusing knob, and find the clear image of this eyepiece (when the monocular adjustable is used, first adjust the focusing knob to make this eyepiece image clear), then adjust the image of another eyepiece tube (do not adjust the focusing knob again at this time), repeatedly adjust to find the clear position, then the two images are clear at the same time. For this particular user, do not adjust this device anymore in the future.
As some microscopes do not have the vision adjustment mechanism for the eyepiece tube, the vision of the two eyes are adjusted through the eyepiece adjustable.
Eyepiece Optical MagnificationClose Λ
Eyepiece optical magnification is the visual magnification of the virtual image after initial imaging through the eyepiece. When the human eye observes through the eyepiece, the ratio of the tangent of the angle of view of the image and the tangent of the angle of view of the human eye when viewing or observing the object directly at the reference viewing distance is usually calculated according to 250 mm/focal length of eyepiece.
The standard configuration of a general microscope is a 10X eyepiece.
Usually, the magnification of the eyepiece of compound microscope is 5X, 8X, 10X, 12.5X, 16X, 20X.
As stereo microscope has a low total magnification, its eyepiece magnification generally does not use 5X, but can achieve 25X, 30X and other much bigger magnification.
Eyepiece Field of ViewClose Λ
The eyepiece field of view is the diameter of the field diaphragm of the eyepiece, or the diameter of the image plane of the field diaphragm imaged by the field diaphragm.
The diameter of a large field of view can increase the viewing range, and see more detail in the field of view. However, if the field of view is too large, the spherical aberration and distortion around the eyepiece will increase, and the stray light around the field of view will affect the imaging effect.
Eyepoint TypeClose Λ
Eye point refers to the axial distance between the upper end of the metal frame of the eyepiece and the exit of pupil.
The exit of pupil distance of high eyepoint eyepiece is farther than that of the eye lens of the ordinary eyepiece. When this distance is greater than or equal to 18mm, it is a high eyepoint eyepiece. When observing, one does not need to be too close to the eyepiece lens, making it comfort to observe, and it can also be viewed with glasses. Generally, there is a glasses logo on the eyepiece, indicating that it is a high eyepoint eyepiece.
Built-in Objective MagnificationClose Λ
The objective of a stereo microscope is mostly built-in objective, which is usually mounted in the microscope body, and it is one or a set of lenses closest to the object to be observed.
When not marked, the built-in objective is 1X.
Post StandClose Λ
Post stand generally has relatively tall post. When the focus is adjusted, the focusing mechanism can slide up and down the post, the microscope is thus placed in an approximately focused position, and then the focusing mechanism makes fine and accurate adjustment. This kind of stand can move quickly, and is suitable for viewing objects with a higher height and bigger volume.
After the microscope is mounted, the microscope imaging center needs to be aligned with the center of the platen.
The focusing mechanism button on the post must be tightened to lock the guard ring device, and the microscope should be prevented from loosening and shaking when working. When it is necessary to adjust the height, hold the microscope and the focusing mechanism with one hand, then release the knob, adjust it to the proper position, lock the knob, then top the guard ring to the lower position of the focusing mechanism, and lock it tight. In particular, avoid accidental dropping of the microscope due to gravity, thereby damaging the microscope and the objects below.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.

 


Optical Data

 


Microscope Optical Data Sheet
P/NObjectiveObjective Working DistanceEyepiece
FS12013111   (5X  Dia. 20mm)FS12050125   (10X  Dia. 20mm)FS12013232   (10X  Dia. 20mm)FS12013411   (15X  Dia. 15mm)FS12013611   (20X  Dia. 10mm)
MagnificationField of View(mm)MagnificationField of View(mm)MagnificationField of View(mm)MagnificationField of View(mm)MagnificationField of View(mm)
FS120501250.8X4X25mm8X25mm8X25mm12X18.75mm16X12.5mm
1. Magnification=Objective Optical Magnification * Body Magnification * Eyepiece Optical Magnification
2. Field of View=Eyepiece Field of View /(Objective Optical Magnification*Body Magnification)
3. The Darker background items are Standard items, the white background items are optional items.



Contains  
Parts Including
Desiccant Bag1 Bag
Product Instructions/Operation Manual1pc
Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Packaging Dimensions(1)29.5x18x45.5cm (11.614x7.087x17.913″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsExpanded Polystyrene
Gross Weight3.35kg (7.39lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)29.5x18x45.5cm (11.614x7.087x17.913″)
Total Gross Weight of Transportation(kilogram)3.35
Total Gross Weight of Transportation(pound)7.40

Related Products