Instruction Manual
SZ0503 Zoom Body Instruction Manual-English.doc
Quick Overview
Finite. Total Magnification: 3.5-45X. 10X High Eyepoint Eyepiece. 0.5X Objective. Zoom Ratio: 1:6.5. Binocular. Body Mounting Size for Stand: Dia. 76mm. Eye Tube Angle: 45°. Eyepiece Field of View: Dia. 20mm. Dual Arm Stand. LED Light. Light Adjustable. Input Voltage: AC 100-240V 50/60Hz.
Suggested Applications
Industrial , Aerospace, Automotive, Dental Lab & Production, Mechanical Parts, Plastics, Quality Assurance & Failure Analysis, Textiles & Fibers, Tool Making
SZ0503 Zoom Body Instruction Manual-English.doc
Quick Overview
Finite. Total Magnification: 3.5-45X. 10X High Eyepoint Eyepiece. 0.5X Objective. Zoom Ratio: 1:6.5. Binocular. Body Mounting Size for Stand: Dia. 76mm. Eye Tube Angle: 45°. Eyepiece Field of View: Dia. 20mm. Dual Arm Stand. LED Light. Light Adjustable. Input Voltage: AC 100-240V 50/60Hz.
Suggested Applications
Industrial , Aerospace, Automotive, Dental Lab & Production, Mechanical Parts, Plastics, Quality Assurance & Failure Analysis, Textiles & Fibers, Tool Making
SZ02010523 Binocular Zoom Stereo Microscope
Optical System Specifications
Optical System | Finite |
System Optical Magnification | 3.5-45X |
Expandable System Optical Magnification (Optional Parts Required) | 3.5-180X |
Total Magnification | 3.5-45X |
Standard Eyepiece | 10X High Eyepoint Eyepiece |
Standard Objective | 0.5X Objective |
System Field of View | Dia. 8.89-57.14mm |
Expandable System Field of View | Dia. 1.11-57.14mm |
System Working Distance | 165mm |
Expandable System Working Distance | 33-165mm |
Binocular Zoom Body
Body Optical System | Finite |
Body Magnification | 7-45X |
Zoom Range | 0.7-4.5X |
Zoom Ratio | 1:6.5 |
Zoom Operating Mode | With Two Horizontal Knobs |
Observation Method | Binocular |
Body Mounting Size for Stand | Dia. 76mm |
Eye Tube Adjustment Mode | Siedentopf |
Eye Tube Angle | 45° |
Erect/Inverted Image | Erect image |
Eye Tube Rotatable | 360° Degree Rotatable |
Interpupillary Adjustment | 54-76mm |
Eye Tube Inner Diameter | Dia. 30mm |
Eye Tube Diopter Adjustable | ±5° |
Eyepiece Type | Standard Eyepiece |
Eyepiece Optical Magnification | 10X |
Plan Eyepiece | Plan Eyepiece |
Eyepiece Size for Eye Tube | Dia. 30mm |
Eyepiece Field of View | Dia. 20mm |
Eyepoint Type | High Eyepoint Eyepiece |
Eyepiece Size for Reticle | Dia. 24mm |
Eye Guard Installation | Independent Eye Guard |
Eye Guard Mount Size | Dia. 36mm |
Built-in Objective Magnification | 1X |
Objective Working Distance | 100mm |
Objective Screw Thread | M48x0.75mm |
Surface Treatment | Spray Paint |
Material | Metal |
Color | White |
Net Weight | 1.49kg (3.28lbs) |
Stereo Auxiliary Lens
0.5X Auxiliary Objective | |
Objective Optical System | Finite |
Objective Optical Magnification | 0.5X |
Objective Type | Achromatic Objective |
Objective Working Distance | 177mm |
Objective Screw Thread | M48x0.75mm |
Objective Outer Diameter | Dia. 49.5mm |
Barlow Lens | Yes |
Surface Treatment | Electroplating Black |
Material | Metal |
Color | Black |
Net Weight | 0.08kg (0.18lbs) |
Applied Field | For SZ0501, SZ0502 Microscope, Nikon SMZ745 Microscope, Olympus SZ30/SZ40/SZ61 Microscope |
Dual Arm Stand
Dual Arm Boom Stand with 76mm E-Arm (White) | |
Stand Type | Dual Arm Stand |
Vertical Post Height | 380mm |
Vertical Post Diameter | Dia. 32mm |
Cross Adapter Type | Triple (3) Hole Adapter |
Horizontal Arm Type | Double Bar |
Horizontal Arm Length | 520mm |
Horizontal Diameter | Dia. 20mm |
Mounting Hole on the Top of Horizontal Arm | Dia. 32mm |
Horizontal Rotation Angle | 360° Degree Rotatable |
Horizontal Arm Travel Distance on Z-Axis | 200mm |
Horizontal Arm Stretch Range | 230mm |
Horizontal Arm Travel Mode on Horizontal Direction | Ball Bearing |
Horizontal Arm Travel Mode on Z Direction | Manual |
Base Type | Heavy Duty Base |
Base Shape | Rectangle |
Base Dimensions | 260x210x50mm |
Arbor Length | 200mm |
Arbor Diameter | Dia. 32mm |
Arbor Rotation Range on Z Direction | 180° |
Arbor Adapter Type | Fixed |
Safety Cover Thread Size of Arbor | Dia. 24x1mm |
Safety Protection Against Falling Screw | With Safety protection against falling Screw |
Surface Treatment | Spray Paint |
Material | Metal |
Color | White |
Net Weight | 20.15kg (44.42lbs) |
Dimensions | 700x210x430mm (27.560x8.268x16.929 in. ) |
Focus Rack
76/32mm Through Hole Focus Rack | |
Holder Adapter Type | Dia. 76mm Scope Holder |
Focus Mode | Manual |
Focus Distance | 50mm |
Coarse Focus Distance per Rotation | 25mm |
Post Hole Diameter of Focusing Rack | Dia. 32mm |
Center Distance from Hole to Scope Holder | 146mm |
Surface Treatment | Spray Paint |
Material | Metal |
Color | White |
Net Weight | 1.05kg (2.31lbs) |
Ring Light
LED Ring Light (4W ID61mm 64Bulbs) | |
Light Source Type | LED Light |
Ring I.D. Size | Dia. 61mm |
LED Quantity | 64 |
Power Supply Adjustable | Light Adjustable |
Light Source Illuminance | 16000Lux or more |
Bulb Color Temperature | 6400K |
Output Power | 4W |
Input Voltage | AC 100-240V 50/60Hz |
Output Voltage | DC 12V |
Power Cord Connector Type | USA 2 Pins |
Power Cable Length | 1.8m |
Material | Plastic |
Color | White |
Net Weight | 0.15kg (0.33lbs) |
Screw Model | M3x24mm |
Other Parameters
Surface Treatment | Spray Paint |
Material | Metal |
Color | White |
Net Weight | 21.8kg (48.09lbs) |
This Kit Includes | SZ05034211, SZ05031121, ML23241122, SZ05033611, ST19061101 |
Series
SZ0503 | SZ02010523 |
Technical Info
Instructions
Stereo MicroscopeClose Λ
Stereo microscopes are also known as the anatomical microscopes, or dissecting microscopes. Many people would refer to stereo microscope as Stereo, and the Continuous Zoom Microscope as Zoom. Stereo microscopes are a kind of binocular microscope that observes an object with both eyes from different angles, thereby causing a stereoscopic effect. The stereo microscope adopts two independent optical paths, and the left and right beams in the binocular tube have a certain angle, generally 12°~15°. The objects are observed from different angles of the two optical paths, causing a three-dimensional effect on the eyes, and therefore a stereo microscope is a true 3D microscope. Compared with other compound microscopes, stereo microscopes belong to the low power optical microscope. The field of view of stereo microscopes has a large diameter, its magnification is generally below 200X for optical magnification. When the magnification is greater than 40X, the stereoscopic effect of the image will be relatively poor. Therefore, the advantage of the stereo microscope is not that its magnification is large, but that its working distance is long and the depth of field is large, which is particularly suitable for observing objects with a high degree of three-dimensional features. For compound microscope with a single optical path, what we see is only a flat image. Although most compound microscopes have two eyepieces, what we actually see is one and the same image, and this is just to facilitate the observation habits of our two eyes. The stereo microscope has two optical paths (two objective lenses or one common objective lens), and only the three-dimensional sense produced under observation of the two optical paths can make people judge the three-dimensional spatial position of the observed object, which can generate a sense of distance under the microscope. Therefore, only stereo microscope can be used for operation under the microscope which is very suitable for surgery, dissection, industrial welding, assembly, precision instrument repair and so on. The stereo microscope can be equipped with a wide range of accessories. It can be combined with various digital cameras and photographic interfaces, microscope cameras, eyepiece cameras and image analysis software to form a digital imaging system. It can be connected to a computer for analysis and processing, and its lighting system also has different options for illumination, such as reflected light, transmitted light, etc. Stereoscopic microscopes are widely used in various fields, such as biology, medicine, agriculture, forestry, marine life, and other various departments. They are especially used in industry, for macroscopic surface observation, analysis, and microscopic operations. Stereoscopic microscopes were invented by American instrument engineer Horatio S. Greenough in the 1890s, manufactured by Carl Zeiss Company of Germany, and are widely used in scientific research, archaeological exploration, industrial quality control, biopharmaceuticals, and more. Stereo Microscope Quick Operation Steps Step 1 In the working position, place the microscope on the workbench after installation. Connect the power source, and turn on the light source. Place an observation sample (also known as specimen) such as a coin etc. under the microscope or on the base. Adjust the focus knob of the stand by visually measuring the height, or based on the working distance parameters of the objective lens used. Step 2 Adjust the zoom knob of the microscope to the lowest magnification. Find the approximate image by adjusting the focus knob. Find a certain feature point of the sample in approximately the center position. Align the feature point of the specimen and gradually adjust to a large magnification. Adjust the lift set of the microscope to find the focal plane of the highest magnification. During the adjustment process, use a sample with obvious feature points (such as a coin) to compare the sharpness of the image. Turn the zoom knob again to the lowest magnification. It is possible that the image may be out of focus. At this time, do not adjust the focusing knob. Simply adjust the diopters on the two eyepieces to accommodate differences in eye observations (diopter varies from person to person). Adjust the viewing distance of the eyepiece to achieve a comfortable position. At this point, the microscope is already parfocal, i.e., when the microscope is changed from high power to low power, the entire image is in the focal plane. To observe the same sample, it is not necessary to adjust other parts of the microscope. Only the zoom knob is needed to zoom in on the specimen for observation. Step 3 Adjust the light source, including the brightness and angle of incidence to get the best image or see additional details. Step 4 Adjust any other necessary equipment such as the photographic eyepieces, cameras, etc., to show the image on the display or to find the sharpest image. When using binocular observation and the left and right images or sharpness is not the same, first adjust the diopter adjustment on the eyepiece. This adjusts the parallax of the two eyes, so that the image of the two eyes are consistent. It is normal to feel viewing fatigue when using a microscope for a long time. Take a break before working again to adapt your eyes to using the microscope. If the microscope is used for too long, or if there is a problem inside the microscope due to large temperature difference, vibration, etc., please contact your dealer or our service staff on the BoliOptics website. |
FiniteClose Λ
Microscopes and components have two types of optical path design structures. One type is finite optical structural design, in which light passing through the objective lens is directed at the intermediate image plane (located in the front focal plane of the eyepiece) and converges at that point. The finite structure is an integrated design, with a compact structure, and it is a kind of economical microscope. Another type is infinite optical structural design, in which the light between the tube lens after passing the objective lens becomes "parallel light". Within this distance, various kinds of optical components necessary such as beam splitters or optical filters call be added, and at the same time, this kind of design has better imaging results. As the design is modular, it is also called modular microscope. The modular structure facilitates the addition of different imaging and lighting accessories in the middle of the system as required. The main components of infinite and finite, especially objective lens, are usually not interchangeable for use, and even if they can be imaged, the image quality will also have some defects. The separative two-objective lens structure of the dual-light path of stereo microscope (SZ/FS microscope) is also known as Greenough. Parallel optical microscope uses a parallel structure (PZ microscope), which is different from the separative two-object lens structure, and because its objective lens is one and the same, it is therefore also known as the CMO common main objective. |
System Optical MagnificationClose Λ
The magnification of the objective lens refers to the lateral magnification, it is the ratio of the image to the real size after the original image is magnified by the instrument. This multiple refers to the length or width of the magnified object. System optical magnification is the product of the eyepiece and the objective lens (objective lens zoom set) of the optical imaging part within the system. Optical magnification = eyepiece multiple X objective lens/objective lens set The maximum optical magnification of the microscope depends on the wavelength of the light to which the object is illuminated. The size of the object that can be observed must be greater than the wavelength of the light. Otherwise, the light cannot be reflected or transmitted, or recognized by the human eye. The shortest wavelength of ultraviolet light is 0.2 microns, so the resolution of the optical microscope in the visible range does not exceed 0.2 microns, or 200 nanometers. This size is converted to the magnification of the microscope, and it is the optical magnification of 2000X. Usually, the compound microscope can achieve 100X objective lens, the eyepiece is 20X, and the magnification can reach 2000X. If it is bigger, it will be called "invalid magnification", that is, the image is large, but the resolution is no longer increased, and no more details and information can be seen. |
Total MagnificationClose Λ
Total magnification is the magnification of the observed object finally obtained by the instrument. This magnification is often the product of the optical magnification and the electronic magnification. When it is only optically magnified, the total magnification will be the optical magnification. Total magnification = optical magnification X electronic magnification Total magnification = (objective X photo eyepiece) X (display size / camera sensor target ) |
System Field of ViewClose Λ
Field of View, is also called FOV. The field of view, or FOV, refers to the size of the object plane (i.e., the plane of the point of the observed object perpendicular to the optical axis), or of its conjugate plane (i.e., object to primary image distance), represented by a line value. System field of view is the size of the actual diameter of the image of the terminal display device of the instrument, such as the size of the image in the eyepiece or in the display. Field of view number refers to the diameter of the field diaphragm of the objective lens, or the diameter of the image plane formed by the field diaphragm. Field of view number of objective lens = field of view number of eyepiece / (objective magnification / mechanical tube length) Large field of view makes it easy to observe the full view and more range of the observed object, but the field of view (FOV) is inversely proportional to the magnification and inversely proportional to the resolution, that is, the larger the field of view, the smaller the magnification, and also the lower the resolution of the object to be observed. There are usually two ways to increase the field of view, one is to replace with an objective lens of a smaller multiple, or to replace with an eyepiece of a smaller multiple. |
System Working DistanceClose Λ
Working distance, also referred to as WD, is usually the vertical distance from the foremost surface end of the objective lens of the microscope to the surface of the observed object. When the working distance or WD is large, the space between the objective lens and the object to be observed is also large, which can facilitate operation and the use of corresponding lighting conditions. In general, system working distance is the working distance of the objective lens. When some other equipment, such as a light source etc., is used below the objective lens, the working distance (i.e., space) will become smaller. Working distance or WD is related to the design of the working distance of the objective lens. Generally speaking, the bigger the magnification of the objective lens, the smaller the working distance. Conversely, the smaller the magnification of the objective lens, the greater the working distance. When it is necessary to change the working distance requirement, it can be realized by changing the magnification of the objective lens. |
Binocular Zoom BodyClose Λ
Binocular zoom body is the main body of a stereo microscope that has continuous zooming functions and observes with two eyepieces. This body usually needs to be placed on a microscope stand for use. Generally, a variety of eyepieces and objective lenses with different magnifications can be selected. A high-end stereo microscope usually has a wide range of accessories for selection. |
Zoom RangeClose Λ
Zoom in zoom microscope means to obtain different magnifications by changing the focal length of the objective lens within a certain range through adjustment of some lens or lens set while not changing the position of the object plane (that is, the plane of the point of the observed object perpendicular to the optical axis) and the image plane (that is, the plane of the image imaging focus and perpendicular to the optical axis) of the microscope. Zoom range refers to the range in which the magnification is from low to high. In the zoom range of the microscope, there is no need to adjust the microscope knob for focusing, and ensure that the image is always clear during the entire zoom process. The larger the zoom range, the stronger the adaptability of the range for microscope observation, but the image effects at both ends of the low and high magnification should be taken into consideration, the larger the zoom range, the more difficult to design and manufacture, and the higher the cost will be. |
Zoom RatioClose Λ
Zoom ratio is the ratio of the maximum magnification / the minimum magnification. Expressed as 1: (ratio of maximum magnification / minimum magnification). If the maximum magnification is 4.5X, the minimum magnification is 0.7X, then the zoom ratio = 4.5 / 0.7 = 6.4, the zoom ratio will be 1:6.4. Zoom ratio is obtained by the intermediate magnification group of the microscope. When the magnification is increased or decreased by using other objective lenses, the zoom ratio does not change accordingly. |
With Two Horizontal KnobsClose Λ
When microscope body changes the magnification, it is realized by adjusting the horizontally placed zoom knob. Because the knob is relatively small, it is therefore easier to zoom and the image is stable. For most of the dual stereo microscopes, magnification is realized by adjusting the zoom drum or nosepiece below. When the nosepiece is relatively big, frequent operation is more laborious. Magnifying while observing, the microscope may shake, thereby causing eye discomfort for observation. Using zoom drum or nosepiece type microscope, if there is a ring light under the microscope, the ring light carries the wire, and when magnification conversion is often required, the ring light and the wire will swing along with the magnification, which makes the operation inconvenient. This situation will not occur to zoom with two horizontal knobs. |
SiedentopfClose Λ
For siedentopf eyetube, when changing the interpupillary distance, it requires two hands pushing or pulling the two eyetubes left and right simultaneously, and the two eyepiece tubes or eyetubes will change their position at the same time. |
Eye Tube AngleClose Λ
Usually the Microscope Eyetube is 45°, some is 30°, Tiltable Eyetube Angle design of a microscope is also known as the ergonomics microscope. 0-30° or 0-45° is an ergonomic design. When the mechanical tube length / focal length of the tube of the microscope is relatively big, the microscope is relatively high, and the user's height or the seat of the work desk is not suitable, long-term use of microscope may cause sitting discomfort. Eyepiece tube with variable angle can freely adjust the angle without lowering the head. Especially when it is close to 0 degree and the human eye is close to horizontal viewing, long-time or long-term use can avoid fatigue damage to the cervical vertebra. |
Erect/Inverted ImageClose Λ
After imaging through a set of objective lenses, the object observed and the image seen by the human eye is inverted. When the observed object is manipulated, move the specimen or object, the image will move in the opposite direction in the field of view. Most of the biological microscopes are reversed-phase designs. When needing to operate works with accurate direction, it is necessary to design it into a forward microscope. Generally stereo microscopes and metallurgical microscopes are all of erect image design. When observing through the camera and display, the erect and inverted image can be changed by the orientation of the camera. |
360° Degree RotatableClose Λ
The eyepiece of the microscope can have different viewing or observing directions. When the position of the microscope is uncomfortable, the direction of the eyepiece tube of the microscope can be adjusted, to facilitate observation and operation. Placement method of different viewing angles of the microscope: General direction: the support column is behind the object to be observed Reverse direction: the support column is in front of the object to be observed Lateral direction: the support column is on the side of the object to be observed Rotating eyepiece tube, different microscopes may have different methods, for some, the direction is confirmed when installing the eyepiece tube of the microscope, for some, by rotating the body of the microscope, and for some, by rotating the support member on the support or holder of the microscope. |
Interpupillary AdjustmentClose Λ
The distance between the two pupils of the human eye is different. When the image of exit pupil of the two eyepieces of the microscope are not aligned with the entry pupil of the eye, the two eyes will see different images, which can cause discomfort. Adjust the distance between the two eyepieces, to accommodate or adapt to the pupil distance of the observer's eyes. The adjustment range is generally between 55-75mm. |
Eye Tube Diopter AdjustableClose Λ
For most people, their two eyes, the left and the right, have different vision; for the eyepiece tube, the eyepoint height of the eyepiece can be adjusted to compensate for the difference in vision between the two eyes, so that the imaging in the two eyes is clear and consistent. The range of adjustment of the eyepiece tube is generally diopter plus or minus 5 degrees, and the maximum differential value between the two eyepieces can reach 10 degrees. Monocular adjustable and binocular adjustable: some microscopes have one eyepiece tube adjustable, and some have two eyepiece tubes adjustable. First, adjust one eyepiece tube to the 0 degree position, adjust the microscope focusing knob, and find the clear image of this eyepiece (when the monocular adjustable is used, first adjust the focusing knob to make this eyepiece image clear), then adjust the image of another eyepiece tube (do not adjust the focusing knob again at this time), repeatedly adjust to find the clear position, then the two images are clear at the same time. For this particular user, do not adjust this device anymore in the future. As some microscopes do not have the vision adjustment mechanism for the eyepiece tube, the vision of the two eyes are adjusted through the eyepiece adjustable. |
Eyepiece Optical MagnificationClose Λ
Eyepiece optical magnification is the visual magnification of the virtual image after initial imaging through the eyepiece. When the human eye observes through the eyepiece, the ratio of the tangent of the angle of view of the image and the tangent of the angle of view of the human eye when viewing or observing the object directly at the reference viewing distance is usually calculated according to 250 mm/focal length of eyepiece. The standard configuration of a general microscope is a 10X eyepiece. Usually, the magnification of the eyepiece of compound microscope is 5X, 8X, 10X, 12.5X, 16X, 20X. As stereo microscope has a low total magnification, its eyepiece magnification generally does not use 5X, but can achieve 25X, 30X and other much bigger magnification. |
Eyepiece Field of ViewClose Λ
The eyepiece field of view is the diameter of the field diaphragm of the eyepiece, or the diameter of the image plane of the field diaphragm imaged by the field diaphragm. The diameter of a large field of view can increase the viewing range, and see more detail in the field of view. However, if the field of view is too large, the spherical aberration and distortion around the eyepiece will increase, and the stray light around the field of view will affect the imaging effect. |
Eyepoint TypeClose Λ
Eye point refers to the axial distance between the upper end of the metal frame of the eyepiece and the exit of pupil. The exit of pupil distance of high eyepoint eyepiece is farther than that of the eye lens of the ordinary eyepiece. When this distance is greater than or equal to 18mm, it is a high eyepoint eyepiece. When observing, one does not need to be too close to the eyepiece lens, making it comfort to observe, and it can also be viewed with glasses. Generally, there is a glasses logo on the eyepiece, indicating that it is a high eyepoint eyepiece. |
Independent Eye GuardClose Λ
The main function of the eye guard is to block the ambient stray light, which makes it more clearer when observing through the eyepiece. In addition, the height of the eye guard is basically the eyepoint exit pupil distance of the eyepiece, and when the eye is close to the eye guard, it is the exact position for clear imaging. |
Built-in Objective MagnificationClose Λ
The objective of a stereo microscope is mostly built-in objective, which is usually mounted in the microscope body, and it is one or a set of lenses closest to the object to be observed. When not marked, the built-in objective is 1X. |
Objective Working DistanceClose Λ
The objective working distance is the vertical distance from the foremost surface end of the objective of the microscope to the object surface to be observed. Generally, the greater the magnification, the higher the resolution of the objective, and the smaller the working distance, the smaller the field of view. Conversely, the smaller the magnification, the lower the resolution of the objective, and the greater the working distance, and greater the field of view. High-magnification objectives (such as 80X and 100X objectives) have a very short working distance. Be very careful when focusing for observation. Generally, it is after the objective is in position, the axial limit protection is locked, then the objective is moved away from the direction of the observed object. The relatively greater working distance leaves a relatively large space between the objective and the object to be observed. It is suitable for under microscope operation, and it is also easier to use more illumination methods. The defect is that it may reduce the numerical aperture of the objective, thereby reducing the resolution. |
Objective Screw ThreadClose Λ
For microscopes of different manufacturers and different models, the thread size of their objectives may also be different. In general, the objective threads are available in two standard sizes, allowing similar objectives between different manufacturers to be used interchangeably. One is the British system: RMS type objective thread: 4/5in X 1/36in, One is metric: M25 X 0.75mm thread. |
Objective Optical MagnificationClose Λ
The finite objective is the lateral magnification of the primary image formed by the objective at a prescribed distance. Infinite objective is the lateral magnification of the real image produced by the combination of the objective and the tube lens. Infinite objective magnification = tube lens focal length (mm) / objective focal length (mm) Lateral magnification of the image, that is, the ratio of the size of the image to the size of the object. The larger the magnification of the objective, the higher the resolution, the smaller the corresponding field of view, and the shorter the working distance. |
Objective TypeClose Λ
In the case of polychromatic light imaging, the aberration caused by the light of different wavelengths becomes chromatic aberration. Achromatic aberration is to correct the axial chromatic aberration to the two line spectra (C line, F line); apochromatic aberration is to correct the three line spectra (C line, D line, F line). The objective is designed according to the achromaticity and the flatness of the field of view. It can be divided into the following categories. Achromatic objective: achromatic objective has corrected the chromatic aberration, spherical aberration, and comatic aberration. The chromatic portion of the achromatic objective has corrected only red and green, so when using achromatic objective, yellow-green filters are often used to reduce aberrations. The aberration of the achromatic objective in the center of the field of view is basically corrected, and as its structure is simple, the cost is low, it is commonly used in a microscope. Semi-plan achromatic objective: in addition to meeting the requirements of achromatic objective, the curvature of field and astigmatism of the objective should also be properly corrected. Plan achromatic objective: in addition to meeting the requirements of achromatic objectives, the curvature of field and astigmatism of the objective should also be well corrected. The plan objective provides a very good correction of the image plane curvature in the field of view of the objective, making the entire field of view smooth and easy to observe, especially in measurement it has achieved a more accurate effect. Plan semi-apochromatic objective: in addition to meeting the requirements of plan achromatic objective, it is necessary to well correct the secondary spectrum of the objective (the axial chromatic aberration of the C line and the F line). Plan apochromatic objective: in addition to meeting the requirements of plan achromatic objective, it is necessary to very well correct the tertiary spectrum of the objective (the axial chromatic aberration of the C line, the D line and the F line) and spherochromatic aberration. The apochromatic aberration has corrected the chromatic aberration in the range of red, green and purple (basically the entire visible light), and there is basically no limitation on the imaging effect of the light source. Generally, the apochromatic aberration is used in a high magnification objective. |
Dual Arm StandClose Λ
Dual arm stand is also called double bar stand, or ball bearing boom stand. The method of use of dual arm stand and most of its parameters are mostly the same as that of the boom stand. The difference is that the cross arm has two rods, and is held by one set of bearings, so that the two cross arms can be freely pulled and moved, and they are vertical and cannot be tilted left and right, making it more free and stable than the use of the dual arm stand in the horizontal direction. It is especially suitable for users who need to frequently push and pull, observe and adjust the position in horizontal direction. |
Focus RackClose Λ
Focus rack is the focusing mechanism that connects the microscope, with one end connected to the post of the microscope stand to adjust the up and down movement of the microscope for focusing. The front end of the focus rack can also be used to connect microscopes or cameras of different diameters by changing the scope holder. |
Dia. 76mm Scope HolderClose Λ
The 76mm stand scope holder is the most popular microscope body adapter size, suitable for stereo microscopes produced by most manufacturers. Place the microscope body in a 76mm scope holder, tighten with screws to avoid shaking when the microscope is in use. Because this stand scope holder is very common, some special-sized microscopes can also borrow and use this stand, but only need a specific adapter to connect the microscope body with a diameter of less than 76mm. |
Ring LightClose Λ
Ring light is a kind of "shadowless lamp", which is illuminated from a 360-degree annular angle, and can observe the change of the edge and height of the object to be observed. It is very suitable for surface illumination of non-reflective objects, and is often used to observe and detect the edge of objects, surface structure, traces, etc. such as components on the printed circuit board, liquid crystal glass substrates, metal and non-metal surface dust, scratch damage, various kinds of particles, etc., and is also the most common way of illumination for stereo microscopes. Circular fluorescent light bulb is a bulb of peripheral illumination with no direction, it requires a reflective bowl to converge the light beam onto the illuminated object below the microscope. The diameter of the tube and the design of the reflective bowl determine the distance and position of the beam convergence point. The LED ring light consists of different LED bulbs. By setting the angle of the bulb, all the illumination beams are concentrated at one focus, and the annular or loop fiber is mostly designed by the incident angle of the fiber exit port. The central concentration range of the ring lamp usually needs to coincide with the focal length of the objective lens of the stereo microscope. The working distance of the 1X objective lens of stereo microscope is generally about 80-100mm, which is the focus convergence position of most of the ring lamps. Because the external light source itself has a certain height, therefore the concentration center range of the ring light source is generally between 45-65mm. If below 45mm, shadow starts to appear in the middle; if higher than 65mm, the light in the middle will gradually diverge, and the brightness will decrease. When a small objective lens (such as 0.75X/0.5X) is selected, the lighting effect can basically be achieved; but when an objective lens with larger magnification is used and the working distance is relatively small (for example, 2X), the illumination center of the ring lamp will be a "black center", the effect of lighting will be relatively poor. Ring lights are usually stuck at the bottom of the nosepiece. Tighten the screws. In general, the electrical wires should be pulled to the back of the operating position, the switch or button should be placed on the side for easy operation. Generally, the ring light needs to be stuck with a lens frame at the bottom of the nosepiece. On the objective frame, there is a card slot for screw fastening. There are also microscope nosepieces that contains a card slot position of its own, and does not need an objective frame. |
Light AdjustableClose Λ
The brightness of the light source adjustable is very important in the imaging of the microscope. Since the difference of the numerical aperture of the objective lens of high magnification and low magnification is very big, more incident light is needed to achieve a much better resolution when using a high magnification objective lens. Therefore, when observing through a high magnification objective lens, the brightness required is high; when observing through a low magnification objective lens, the brightness required is low. When observing different objects, or feature points of the same object at different positions, the brightness needs are also different; including the difference of background light or reflection within the field of view of observation, it has a great influence on the effect of observing the object, and therefore one needs to adjust the brightness of the light source according to each object to be observed. In the light source capable of providing continuous spectrum, such as a halogen lamp, the brightness adjustment of the light not only adjusts the brightness and intensity of the light, but also changes the spectrum emitted by the light source. When the light source is dark, there are many components of red light, and when the brightness is high, there are more blue spectrum. If the required light is strong and the spectrum needs to be changed, the light can be kept at a brighter intensity, which is solved by adjusting the spectrum by adding a color filter. Take note of the dimming button on the light source, after the On/Off switch is turned on, normally clockwise is to brighten, and counterclockwise is to darken. If it is adjusted to the lowest brightness, the light source should normally be lit. If the naked eye still can't see the object being illuminated brightly, you need to adjust the brightness knob to a much bigger position. Generally, there is scale marking on the dimming knob, which is an imaginary number representing the percentage of brightness, or an electronic digital display, giving the brightness of the light source under the same conditions a marking. |
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection. For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem. |
Optical Data
Microscope Optical Data Sheet | ||||||||||||||||||||
P/N | Objective | Objective Working Distance | Eyepiece | |||||||||||||||||
SZ05033211 (10X Dia. 20mm) | SZ05031121 (10X Dia. 20mm) | SZ19013211 (10X Dia. 20mm) | SZ05033411 (15X Dia. 15mm) | SZ19013411 (15X Dia. 15mm) | SZ05033611 (20X Dia. 10mm) | SZ19013611 (20X Dia. 10mm) | SZ19013711 (25X Dia. 10mm) | SZ19013811 (30X Dia. 8mm) | ||||||||||||
Magnification | Field of View(mm) | Magnification | Field of View(mm) | Magnification | Field of View(mm) | Magnification | Field of View(mm) | Magnification | Field of View(mm) | Magnification | Field of View(mm) | Magnification | Field of View(mm) | Magnification | Field of View(mm) | Magnification | Field of View(mm) | |||
SZ05034211 | 0.5X | 165mm | 3.5-22.5X | 8.89-57.14mm | 3.5-22.5X | 8.89-57.14mm | 3.5-22.5X | 8.89-57.14mm | 5.25-33.75X | 6.67-42.86mm | 5.25-33.75X | 6.67-42.86mm | 7-45X | 4.44-28.57mm | 7-45X | 4.44-28.57mm | 8.75-56.25X | 4.44-28.57mm | 10.5-67.5X | 3.56-22.86mm |
SZ19024211 | 0.5X | 177mm | 3.5-22.5X | 8.89-57.14mm | 3.5-22.5X | 8.89-57.14mm | 3.5-22.5X | 8.89-57.14mm | 5.25-33.75X | 6.67-42.86mm | 5.25-33.75X | 6.67-42.86mm | 7-45X | 4.44-28.57mm | 7-45X | 4.44-28.57mm | 8.75-56.25X | 4.44-28.57mm | 10.5-67.5X | 3.56-22.86mm |
SZ05031121 | 1X | 100mm | 7-45X | 4.44-28.57mm | 7-45X | 4.44-28.57mm | 7-45X | 4.44-28.57mm | 10.5-67.5X | 3.33-21.43mm | 10.5-67.5X | 3.33-21.43mm | 14-90X | 2.22-14.29mm | 14-90X | 2.22-14.29mm | 17.5-112.5X | 2.22-14.29mm | 21-135X | 1.78-11.43mm |
SZ05034511 | 1.5X | 45mm | 10.5-67.5X | 2.96-19.05mm | 10.5-67.5X | 2.96-19.05mm | 10.5-67.5X | 2.96-19.05mm | 15.75-101.25X | 2.22-14.29mm | 15.75-101.25X | 2.22-14.29mm | 21-135X | 1.48-9.52mm | 21-135X | 1.48-9.52mm | 26.25-168.75X | 1.48-9.52mm | 31.5-202.5X | 1.19-7.62mm |
SZ19014511 | 1.5X | 45mm | 10.5-67.5X | 2.96-19.05mm | 10.5-67.5X | 2.96-19.05mm | 10.5-67.5X | 2.96-19.05mm | 15.75-101.25X | 2.22-14.29mm | 15.75-101.25X | 2.22-14.29mm | 21-135X | 1.48-9.52mm | 21-135X | 1.48-9.52mm | 26.25-168.75X | 1.48-9.52mm | 31.5-202.5X | 1.19-7.62mm |
SZ05034611 | 2X | 33mm | 14-90X | 2.22-14.29mm | 14-90X | 2.22-14.29mm | 14-90X | 2.22-14.29mm | 21-135X | 1.67-10.71mm | 21-135X | 1.67-10.71mm | 28-180X | 1.11-7.14mm | 28-180X | 1.11-7.14mm | 35-225X | 1.11-7.14mm | 42-270X | 0.89-5.71mm |
SZ19014611 | 2X | 33mm | 14-90X | 2.22-14.29mm | 14-90X | 2.22-14.29mm | 14-90X | 2.22-14.29mm | 21-135X | 1.67-10.71mm | 21-135X | 1.67-10.71mm | 28-180X | 1.11-7.14mm | 28-180X | 1.11-7.14mm | 35-225X | 1.11-7.14mm | 42-270X | 0.89-5.71mm |
1. Magnification=Objective Optical Magnification * Body Magnification * Eyepiece Optical Magnification | ||||||||||||||||||||
2. Field of View=Eyepiece Field of View /(Objective Optical Magnification*Body Magnification) | ||||||||||||||||||||
3. The Darker background items are Standard items, the white background items are optional items. |
Contains | ||||||||||||||||
Parts Including | ||||||||||||||||
| ||||||||||||||||
Desiccant Bag | 1 Bag | |||||||||||||||
Product Instructions/Operation Manual | 1pc |
Packing | |
Packaging Type | Carton Packaging |
Packaging Material | Corrugated Carton |
Packaging Dimensions(1) | 39x24x36cm (15.354x9.449x14.173″) |
Packaging Dimensions(2) | 52x52x23cm (20.472x20.472x9.055″) |
Packaging Dimensions(3) | 18x15x6cm (7.087x5.906x2.362″) |
Inner Packing Material | Plastic Bag |
Ancillary Packaging Materials | Expanded Polystyrene |
Gross Weight | 24.90kg (54.90lbs) |
Minimum Packaging Quantity | 1pc |
Transportation Carton | Carton Packaging |
Transportation Carton Material | Cardboard Box |
Transportation Carton Dimensions(1) | 39x24x36cm (15.354x9.449x14.173″) |
Transportation Carton Dimensions(2) | 52x52x23cm (20.472x20.472x9.055″) |
Transportation Carton Dimensions(3) | 18x15x6cm (7.087x5.906x2.362″) |
Total Gross Weight of Transportation(kilogram) | 24.90 |
Total Gross Weight of Transportation(pound) | 54.90 |
Quantity of One Transportation Carton | 3pc |